Your browser doesn't support javascript.
loading
Determination of difluorochloromethane in workplace air by direct injection gas chromatography / 中国职业医学
China Occupational Medicine ; (6): 475-477, 2020.
Article in Chinese | WPRIM | ID: wpr-881928
ABSTRACT

OBJECTIVE:

To establish a method of determination of difluorochloromethane in workplace air by direct sampling gas chromatography.

METHODS:

Difluorochloromethane in workplace air was collected with aluminum plastic composite film airbag and then directly injected. Difluorochloromethane was separated by DB-1 capillary column and detected with hydrogen flame ionization detector.

RESULTS:

Good linearity was obtained in the range of 1.50-15 042.90 mg/m~3 with the correlation coefficient of 0.999 96. The limit of detection was 1.26 mg/m~3 and the limit of quantitation was 3.78 mg/m~3. The minimum detection concentration was 1.26 mg/m~3 and the minimum quantification concentration was 3.78 mg/m~3. The standard recovery was 98.34%-99.19%. The within-run relative standard deviation(RSD) and the between-run RSD were 1.82%-3.72% and 2.17%-4.17%, respectively. The samples can be stored at room temperature for at least 7 days.

CONCLUSION:

This method is suitable for difluorochloromethane detection in workplace air.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Occupational Medicine Year: 2020 Type: Article