Your browser doesn't support javascript.
loading
Feasibility study of ultrasound-guided percutaneous endomyocardial septal cryoablation of isolated porcine hearts / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 436-440, 2021.
Article in Chinese | WPRIM | ID: wpr-884344
ABSTRACT

Objective:

To investigate the feasibility of ultrasound-guided percutaneous endomyocardial septal cryoablation of in vitro porcine hearts and to compare its effect with the percutaneous endomyocardial radiofrequency ablation.

Methods:

Experiment 1 Six in vitro porcine hearts were divided into 1 min ( n=2), 3 min ( n=2) and 5 min ( n=2) groups according to the cryoablation time, and all were subjected to ultrasound-guided percutaneous intra-myocardial septal cryoablation at 100% power respectively. After cryoablation, ultrasound images, the size of the solid dissection of the ice ball, and the size of the necrotic area after melting of the frozen ice ball were measured. Experiment 2 The in vitro porcine hearts were divided into cryoablation group ( n=3) and radiofrequency ablation group ( n=3), and ultrasound-guided percutaneous endomyocardial septal cryoablation and radiofrequency ablation were performed with 100% cryo power and 40 W radiofrequency power, and the extent of complete necrotic area and incomplete necrotic area were compared between the two ablation methods after 1 min.

Results:

Experiment 1 In the 1 min cryoablation time group ( n=2), the short diameter of the puck measured by ultrasound was (8.00±0.84)mm, the short diameter of the puck measured by solid was (8.38±1.19)mm, and the short diameter of the necrotic zone measured by solid was (8.35±0.83)mm; in the 3 min group ( n=2), the short diameter of the puck measured by ultrasound was (19.4±0.28)mm, and the short diameter of the puck measured by solid was (19.03±0.33)mm, solid measurement of the short diameter of the necrotic zone was (19.16±0.25)mm; in the 5 min group ( n=2), the short diameter of the puck measured under ultrasound was (26.4±2.54)mm, solid measurement of the short diameter of the puck was (26.01±0.24)mm, and solid measurement of the short diameter of the necrotic zone was (24.82±0.25)mm. Randomized blocks analysis of variance was performed on this data and the difference of block Factor b (freezing time 1 min, 3 min, 5 min) among the three groups was statistically significant( F=505.884, P<0.001). The SNK- q test showed that all three groups differed from each other(all P<0.05). The analysis results for the treatment factors K (measurement modality-ultrasound image measurements, solid anatomical measurements of the puck, and measurements of the necrotic area after melting of the frozen puck) was not statistically significant ( F=0.470, P=0.635). Experiment 2 In the RF ablation group ( n=3), the ratio of incomplete necrotic zone to the radius of the RF ablation area was 0.64±0.01; in the cryoablation group ( n=3), the ratio of incomplete necrotic zone to the radius of the ablation area was 0.26±0.02. The difference was statistically significant( P=0.002) and it can be considered that the incomplete necrotic zone of cryoablation was smaller than that of RF ablation.

Conclusions:

Percutameous intramyocardial septal cryoablation is controllable in scope, ultrasound image evaluation of ablation area is more accurate and incomplete necrosis area is small, which may have potential applications in cardiac ablation.
Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS