Your browser doesn't support javascript.
loading
Shielding calculation and discussion on high energy light source storage ring and synchrotron / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 146-150, 2021.
Article in Chinese | WPRIM | ID: wpr-884489
ABSTRACT

Objective:

To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source.

Methods:

The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding.

Results:

The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%.

Conclusions:

For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.
Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2021 Type: Article