Shielding calculation and discussion on high energy light source storage ring and synchrotron / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection
;
(12): 146-150, 2021.
Article
in Chinese
| WPRIM
| ID: wpr-884489
ABSTRACT
Objective:
To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source.Methods:
The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding.Results:
The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%.Conclusions:
For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.