A case of infra‑nodal Wenckebach conduction block with alternating bundle branch block
International Journal of Arrhythmia
;
: 7-2021.
Article
in English
| WPRIM
| ID: wpr-890969
ABSTRACT
Background@#Atrioventricular (AV) node normally has decremental conduction property and a longer refractory period than His-Purkinje system (HPS). This results in AV conduction delay or block at the level of AV node in response to short-coupled atrial premature beats. Prolonged refractoriness in HPS can produce unusual physiological patterns of AV conduction such as conduction delay or infra-nodal block in the distal elements of HPS.Case presentation We present a case in which atrial premature stimulation produces infra-nodal Wenckebach conduction block which initiates long-short cycle sequence within the bundle branches resulted in alternating bundle branch block and atypical pattern of Ashman phenomenon. @*Conclusions@#This case highlights the importance of recognizing the unusual physiological AV conduction patterns of HPS. The long-short cycle sequence in the bundle branches of distal HPS and linking phenomenon can result in alternating bundle branch block without the presence of HPS disease.