Comparison of Serologic Response of Hospitalized COVID-19 Patients Using 8 Immunoassays
Journal of Korean Medical Science
; : e64-2021.
Article
in En
| WPRIM
| ID: wpr-892283
Responsible library:
WPRO
ABSTRACT
Background@#In Korea, there were issues regarding the use of immunoassays for anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies to detect infection. So, we compared antibody results of eight kinds of commercial immunoassays using clinical remnant specimens. @*Methods@#We compared the results of several immunoassay kits tested on 40 serum samples from 15 confirmed patients and 86 remnant serum samples from clinical laboratory.Eight kinds of IVD kits—four enzyme-linked immunosorbent assay, two lateral flow rapid immunochromatographic assays, and two chemiluminescent immunoassays with one RUO kit were tested. @*Results@#Among 40 serum samples from 15 coronavirus disease 2019 (COVID-19) patients, 35 yielded at least one positive result for detecting antibodies in the combined assessment. There were inconsistent results in 12 (28%) samples by single immunoassay. Forty samples collected in 2019 before the first COVID-19 Korean case showed negative results except for one equivocal result. @*Conclusion@#The discrepant results obtained with different immunoassay kits in this study show that serological assessment of SARS-CoV-2 by a single immunoassay requires caution not only in detecting infection but also in assessing immunologic status.
Full text:
1
Index:
WPRIM
Language:
En
Journal:
Journal of Korean Medical Science
Year:
2021
Type:
Article