Your browser doesn't support javascript.
loading
Ultrasound-guided Transforaminal Epidural Injection in Pigs / 中国康复理论与实践
Chinese Journal of Rehabilitation Theory and Practice ; (12): 550-554, 2020.
Article in Chinese | WPRIM | ID: wpr-905476
ABSTRACT

Objective:

To observe the feasibility and accuracy of ultrasound-guided transforaminal epidural injection.

Methods:

Ultrasound-guided injection at L1-2, L2-3, L3-4, L4-5, L5-6 bilaterally was performed in L1-6 spine from two Bama miniature pigs. The position of needles was detected with X-ray and CT, and observed under anatomy. The distance from the puncturing points at skin to the posterior midline, the depths and angles of puncturing between were measured and compared bilaterally.

Results:

The successful rate was 95% (19/20), out of which, 80% (16/20) were put the needle tips at the lower part of the intervertebral foramen, ventral side, central region or paracentral region. There was no significant difference between sides in the distances, depths or angles in 19 successful injections.

Conclusion:

It is accurate to transforaminally puncture under ultrasound-guided.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Rehabilitation Theory and Practice Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Rehabilitation Theory and Practice Year: 2020 Type: Article