Your browser doesn't support javascript.
loading
Comparison of the efficacy of different venous intubation in venous-arterial extracorporeal membrane oxygenation assisted lung transplantation / 中华危重病急救医学
Chinese Critical Care Medicine ; (12): 1080-1083, 2021.
Article in Chinese | WPRIM | ID: wpr-909456
ABSTRACT

Objective:

To compare the curative effects of different venous cannulas and drainage to improve patient's whole body oxygenation during the auxiliary process of venous-arterial extracorporeal membrane oxygenation (VA-ECMO) in lung transplantation.

Methods:

From December 2016 to December 2019, 12 patients who were assisted by VA-ECMO in one lung transplantation in People's Hospital of Henan Province were selected as the research objects. According to the number of side holes of venous cannulas, they were divided into two groups one group with few side holes and other group with multiple side holes. The differences in blood gas indexes among the right radial artery, left radial artery, and right internal jugular vein before and after assistance were compared, and the assistance effect was evaluated.

Results:

The arterial partial pressure of oxygen (PaO 2) of blood gas indexes of the right and left radial arteries in both groups were significantly higher than that before assistance [mmHg (1 mmHg = 0.133 kPa) right and left radial artery in few side holes group 79.5±4.2 vs. 48.3±3.8 and 88.1±3.5 vs. 48.3±3.8; right and left radial artery in multiple side holes group 67.7±5.9 vs. 48.7±3.2 and 84.0±3.8 vs. 48.7±3.2, all P < 0.05]. The arterial partial pressure of carbon dioxide (PaCO 2) of blood gas index was significantly lower than that before assistance (mmHg 44.2±2.6 vs. 71.7±4.4 for the right radial artery and 44.7±1.4 vs. 71.7±4.4 for the left radial artery in the group with few side holes; 46.2±2.1 vs. 71.2±3.5 for the right radial artery and 44.1±1.9 vs. 71.2±3.5 for the left radial artery in the group with multiple side holes, all P < 0.05). The partial pressure of oxygen in venous blood (PvO 2) of blood gas index of ECMO system in the group with few side holes was significantly lower than that of the multiport side holes group (mmHg 56.4±3.2 vs. 88.7±1.5, P < 0.01), and the partial pressure of carbon dioxide in venous blood (PvCO 2) was significantly higher than that of multiport side holes group (mmHg 63.6±3.7 vs. 44.2±1.7, P < 0.01).

Conclusions:

When VA-ECMO is used in lung transplantation, the superior vena cava blood flow can be fully drained by using intravenous cannula with few side holes. It can effectively improve the oxygenation of the upper body of lung transplant patients, avoid the dilemma of hypoxemia in the upper body and hyperxemia in the lower body, provide more effective assistance to patients undergoing single lung transplantation, and is more meaningful for improving the oxygenation status of the whole body in patients undergoing single lung transplantation.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Critical Care Medicine Year: 2021 Type: Article

Similar