Your browser doesn't support javascript.
loading
Feasibility of the quantitative assessment of blood perfusion in hepatocellular carcinoma by using three-dimensional contrast-enhanced ultrasound / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 932-937, 2021.
Article in Chinese | WPRIM | ID: wpr-910140
ABSTRACT

Objective:

To investigate the clinical feasibility of three-dimensional contrast-enhanced ultrasound (3D-CEUS) in the quantitative assessment of blood perfusion of hepatocellular carcinoma (HCC).

Methods:

Between January 2020 and August 2021, 36 HCC patients (39 lesions in total) confirmed by pathology and clinical diagnosis without any treatment from Zhongshan Hospital, Fudan University were enrolled and underwent both 2D-CEUS and 3D-CEUS examinations. Each examination last for 150 s and all images were recorded, and then the data were analyzed. A region of interest was manually drawn along the margin of the whole tumor and then the time-intensity curve (TIC) generated. The following perfusion parameters were extracted peak intensity (PI), peak time (TTP), ascending slope (AS), mean transit time (MTT) and area under the curve (AUC). After calculating the quality of fit (QOF) of the curve, the intraobserver agreement of the 3D-CEUS quantitative parameters obtained by the same doctor between two times were assessed, and the consistency of the 3D-CEUS and 2D-CEUS quantitative parameters was evaluated when QOF>75%. The differences of the quantitative parameters between different groups (divided by depth of 8 cm and necrosis rate of 50%, respectively) in 3D-CEUS were compared.

Results:

There were 38 lesions (97.4%, 38/39) with QOF>75% in 3D-CEUS. The intraobserver agreement was excellent, the intraclass correlation efficient(ICC) values was 0.85-0.99. The consistency of the time quantitative parameters (TTP and MTT) were high (the ICC values of 0.87 and 0.91), and the correlation of intensity quantitative parameters were substantial, the rs values were 0.71, 0.72 and 0.71. The differences in 3D-CEUS quantitative parameters of the two groups of lesions with different depths were statistically significant (all P<0.05); but there were no significant differences in quantitative parameters between the two groups with different necrosis rate (all P>0.05).

Conclusions:

Quantitative 3D-CEUS is an useful and creditable tool in evaluating the blood perfusion of HCC, especially when the depth of lesion was less than 8 cm.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2021 Type: Article