Your browser doesn't support javascript.
loading
An observational study of the effect of baseline renal cortical blood perfusion with contrast-enhanced ultrasound on short-term outcomes of stent implantation for severe renal artery stenosis / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 944-949, 2021.
Article in Chinese | WPRIM | ID: wpr-910142
ABSTRACT

Objective:

To observe the effect of the cortical blood perfusion parameter of wash-in area under curve (iAUC) with contrast-enhanced ultrasound(CEUS) on the effect of short-term outcomes of stent implantation in patients with severe renal artery stenosis (RAS).

Methods:

Retrospective analysis was performed on 82 patients with unilateral severe RAS who received stent implantation in Beijing Hospital from October 2017 to December 2019. According to the baseline iAUC before CEUS, all patients were divided into the poorly-perfused group (iAUC<850.0 dB×s) (37 cases) and the well-perfused group (iAUC≥850.0 dB×s) (45 cases). Baseline and perioperative clinical-imaging data were analyzed between the two groups. Followed up for 10-12 (11.5±1.7) months, Kaplan-Meier survival curves and Log-rank test were used to analyze the rate of adverse cardiac and renal vascular events and hypertension control rates.

Results:

Compared with the well-perfused group, the poorly-perfused group showed a longer course of hypertension, more diabetic patients, higher systolic blood pressure, diastolic blood pressure, 24 h average systolic blood pressure, and 24 h average diastolic blood pressure, lower glomerular filtration rate, and severe renal artery stenosis. Besides, the iAUC, wash-out AUC and the peak intensity were lower, the average transit time was longer, and the hypoglycemic treatment rate was higher (all P<0.05). Kaplan-Meier survival curve and Log-rank test analysis showed that the occurrence of cardio-renal vascular events ( HR=0.361, 95% CI=0.144-0.907, P=0.012) and renal function deterioration rate ( HR=0.286, 95% CI=0.090-0.914, P=0.035) in the well-perfused group were significantly lower than those in the poorly-perfused group. The blood pressure results demonstrated that the effective rate of hypertension treatment in the well-perfused group was significantly higher than that in the poorly-perfused group (93.3% vs 59.5%, P<0.001), but the improvement rate of hypertension (60.0% vs 43.2%) and cure rate (28.9% vs 16.2%) were not statistically significant between the two groups(all P>0.05).

Conclusions:

Severe RAS patients with decreased baseline iAUC often have diabetes, longer duration of hypertension, significantly reduced glomerular filtration rate and more severe RAS, short-term outcomes are worse with stent implantation.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Observational study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Observational study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2021 Type: Article