ABSTRACT
Intestinal injury is an important toxic response during radiation therapy of pelvic tumors. With the widespread use of precision radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the dose exposed to normal tissues and organs has been significantly reduced. However, the toxic response of the bowel still limits the increase of the dose to the target volume. Therefore, the protection of important organs at risk (OAR), such as the bowel, becomes more and more important while giving adequate irradiated dose to the target volume. Most current studies used loop to contour bowel. For patients who underwent IMRT, the meaningful dose-volume predictors of grade 2 acute intestinal adverse events using bowel loop (small loop + big bowel) delineation included V45 Gy < 50 cm 3,V50 Gy < 13 cm 3, and V55 Gy < 3 cm 3, and the corresponding predicators using bowel bag delineation were V40 Gy < 170 cm 3,V45 Gy < 100 cm 3, and V50 Gy < 33 cm 3.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2021 Type: Article