Implementation and assessment of software based on ESAPI compilation structure / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology
; (6): 1173-1177, 2021.
Article
in Zh
| WPRIM
| ID: wpr-910533
Responsible library:
WPRO
ABSTRACT
Objective:To help clinicians simplify the post-processing operations of structures by developing rapid processing software for target area and organs at risk structures based on ESAPI.Methods:SmartStructure script software was developed based on ESAPI, verified and evaluated in clinical work. 10 cases of rectal cancer receiving neoadjuvant radiotherapy, 10 breast cancer treated with postoperative radiotherapy, 10 cervical cancer receiving postoperative radiotherapy, 10 nasopharyngeal carcinoma receiving radical radiotherapy and 10 lung stereotactic body radiotherapy (SBRT) were selected, and different types of tumors had different post-processing operations of structures. In each case, three methods were used for post-processing of structures. In the control group (manual group), normal manual processing was employed. In the experimental group 1(SmaStru-N group), scripts without templates were utilized. In the experimental group 2(SmaStru-P group). scripts combined with templates were adopted. The processing time of the three methods was compared. Clinicians scored the scripting software from multiple aspects and compared the feeling scores of scripting software and manual operation.Results:All three methods can be normally applied in clinical settings. The error rate in the manual group was 7.0%, 3.0% in the SmaStru-N group 0% in the SmaStru-P group, respectively. Compared with the manual method, SmaStru-N shortened the processing time of target area and organs at risk by 60.9% and 93.3% for SmaStru-P. In addition, SmartStructure was superior to manual method in terms of using feeling scores. Clinicians gave lower score for the" applicability" and" simplicity" , and higher score on the" accuracy" and" efficiency" .Conclusions:Compared with conventional manual structure processing method, SmartStructure software can rapidly and accurately process all structures of the target area and organs at risk, and its advantages become more obvious with the increasing number of structures that need to be processed. SmartStructure software can meet clinical requirements, reduce the error rate, elevate processing speed, improve the working efficiency of clinicians, providing basis for the development of adaptive radiotherapy.
Full text:
1
Index:
WPRIM
Type of study:
Guideline
Language:
Zh
Journal:
Chinese Journal of Radiation Oncology
Year:
2021
Type:
Article