Your browser doesn't support javascript.
loading
Comparison of Four-hook Needle and Memory Alloy Coil 
in Localization of Pulmonary Nodules / 中国肺癌杂志
Chinese Journal of Lung Cancer ; (12): 690-697, 2021.
Article in Chinese | WPRIM | ID: wpr-922242
ABSTRACT
BACKGROUND@#With the extensive development of minimally invasive surgery for pulmonary nodules, preoperative localization becomes more and more critical. There are some defects in traditional localization methods, so it is necessary to improve. The aim of this study was to compare and analyze the safety and effectiveness of two new methods, namely four-hook needle and memory alloy coil, in the localization of pulmonary nodules.@*METHODS@#A retrospective analysis of 152 patients was performed. 76 cases were in four-hook needle group, and 76 cases were in memory alloy coil group. Pulmonary nodules were located before operation, and then video-assisted wedge resection was performed. The average procedure time, localization complications and nodule resection time were counted.@*RESULTS@#The target pulmonary nodules were successfully removed in both groups. In four-hook needle group, 76 patients found localization devices, all the pulmonary nodules were successfully removed, and one case was transferred to open the chest for wedge resection of pulmonary nodules due to severe thoracic adhesion. All 76 patients in memory alloy coil group were successfully resected with pulmonary nodules, and one patient underwent compromising enlarged resection because no lesion was found after the specimen was removed during the operation. There was no significant difference in the incidence of pneumothorax and pulmonary hemorrhage, the success rate of localization and nodule wedge resection time between the two groups. The average time of localization in four-hook needle group was (13.66±3.11) min, lower than that of memory alloy coil group (15.51±3.65) min, and the difference was statistically significant (P=0.001). In memory alloy coil group, when the distance from the nodule to the pleura was ≥1.5 cm and <1.5 cm, the average localization time was (17.20±4.46) min and (14.91±3.15) min, respectively, and there was a statistical difference between the two distance (P=0.044).@*CONCLUSIONS@#Four-hook needle and memory alloy coil have good safety and effectiveness, and the localization time of four-hook needle is shorter. When using memory alloy coil, the effect of the method is better for pulmonary nodules with a distance less than 1.5 cm to pleura.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Tomography, X-Ray Computed / Retrospective Studies / Thoracic Surgery, Video-Assisted / Alloys / Multiple Pulmonary Nodules / Lung Neoplasms Type of study: Observational study Limits: Humans Language: Chinese Journal: Chinese Journal of Lung Cancer Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Tomography, X-Ray Computed / Retrospective Studies / Thoracic Surgery, Video-Assisted / Alloys / Multiple Pulmonary Nodules / Lung Neoplasms Type of study: Observational study Limits: Humans Language: Chinese Journal: Chinese Journal of Lung Cancer Year: 2021 Type: Article