Detection and quantitation of host cell proteins in monoclonal antibody drug products using automated sample preparation and data-independent acquisition LC-MS/MS / 药物分析学报
Journal of Pharmaceutical Analysis ; (6): 726-731, 2021.
Article in Chinese | WPRIM | ID: wpr-931216
ABSTRACT
Ensuring the removal of host cell proteins (HCPs) during downstream processing of recombinant pro-teins such as monoclonal antibodies (mAbs) remains a challenge.Since residual HCPs might affect product stability or safety,constant monitoring is required to demonstrate their removal to be below the regulatory accepted level of 100 ng/mg.The current standard analytical approach for this procedure is based on ELISA;however,this approach only measures the overall HCP content.Therefore,the use of orthogonal methods,such as liquid chromatography-mass spectrometry (LC-MS),has been established,as it facilitates the quantitation of total HCPs as well as the identification and quantitation of the indi-vidual HCPs present.In the present study,a workflow for HCP detection and quantitation using an automated magnetic bead-based sample preparation,in combination with a data-independent acquisi-tion (DIA) LC-MS analysis,was established.Employing the same instrumental setup commonly used for peptide mapping analysis of mAbs allows for its quick and easy implementation into pre-existing workflows,avoiding the need for dedicated instrumentation or personnel.Thereby,quantitation of HCPs over a broad dynamic range was enabled to allow monitoring of problematic HCPs or to track changes upon altered bioprocessing conditions.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Journal of Pharmaceutical Analysis Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Journal of Pharmaceutical Analysis Year: 2021 Type: Article