ABSTRACT
The authors diagnosed femoral component fracture after total knee arthroplasty (TKA) using an anterior-posterior glide mobile-bearing system in a 78-year-old female patient who visited with severe pain and flexion limitations in the left knee and performed revision TKA. The fracture of the femoral component after TKA is a rare complication, and various factors cause the fracture of the femoral component. This case is reported along with a literature review.