Graft Perforation by a Spinal Bony Spur: An Unusual Cause of Late Bleeding after Thoracoabdominal Aorta Replacement
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 186-188, 2019.
Article in English | WPRIM | ID: wpr-939212
ABSTRACT
We report an unusual case of delayed bleeding after open surgical repair of a thoracoabdominal aortic aneurysm. A 79-year-old man developed a massive retroperitoneal hematoma 49 days after Crawford type III thoracoabdominal aorta replacement. During emergency surgery, a tear was found in the prosthetic vascular graft caused by a sharp bony spur arising from the second lumbar vertebral body. This rare, but potentially lethal, complication indicates that attention should be paid to sharp bony structures during open repair of the descending aorta.
Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: The Korean Journal of Thoracic and Cardiovascular Surgery Year: 2019 Type: Article