Objective:
To explore the feasibility and safety of intracardiac ultrasound-assisted atrial septal puncture (ASP) during radiofrequency ablation for atrial fibrillation.Methods:
We enrolled 241 consecutive patients scheduled to radiofrequency ablation for atrial fibrillation in Beijing Anzhen Hospital from July to September 2020. Inclusion criteria patients aged over 18 years with a clear electrocardiogram record of atrial fibrillation. Patients were divided into 2 groups ASP with ultrasound-assisted X-ray (ultrasound group, n=123), ASP under X-ray alone (X-ray group, n=118). Clinical features of patients including age, sex, percent of paroxysmal atrial fibrillation, and repeat ablation, CHA2DS2-VASc score and past history (hypertension, diabetes mellitus, coronary artery disease, stroke/transient ischemic attack (TIA), valve diseases) and echocardiographic parameters (left atrial dimension, left ventricular ejection fraction, left ventricular end-diastolic dimension) were obtained and compared. The first-pass rate, radiation exposure time, duration of ASP, and complications of ASP were also compared between the two groups.Results:
The age of patients in this cohort was (62.5±8.0) years, and the proportion of males was 57.0% (n=138). Among them, the proportion of paroxysmal atrial fibrillation was 56.0% (n=135), and the ratio of repeat ablation was 17.8% (n=43). Age, sex, percent of paroxysmal atrial fibrillation, history of hypertension, diabetes mellitus were similar between the two groups. The first-pass rate was significantly higher in the ultrasound group than in the X-ray group (94.3% (116/123) vs. 79.7% (94/118), P=0.001); the exposure time of X-ray was significantly shorter in the ultrasound group than in the X-ray group ((31.3±7.9) s vs. (124.8±35.7) s, P<0.001), while the duration of ASP was longer in the ultrasound group ((10.1±1.8) minutes vs. (8.2±1.3) minutes, P<0.001). In terms of complications, the incidence of puncture into the pericardium was lower in the ultrasound group (0 vs.3.4% (4/118), P=0.039); the rate of transient ST-segment elevation post ASP was similar between the ultrasound group and X-ray group (2.4% (3/123) vs. 1.7% (2/118), P=0.999).Conclusion:
Intracardiac ultrasound-assisted atrial septal puncture can effectively improve the accuracy of atrial septal puncture, shorten the radiation exposure time, and reduce the complications related to atrial septal puncture.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Atrial Fibrillation
/
Stroke Volume
/
Punctures
/
Feasibility Studies
/
Ventricular Function, Left
/
Catheter Ablation
/
Radiofrequency Ablation
/
Heart Septal Defects, Atrial
Limits:
Adult
/
Aged
/
Humans
/
Male
Language:
Chinese
Journal:
Chinese Journal of Cardiology
Year:
2021
Type:
Article
Similar
MEDLINE
...
LILACS
LIS