Construction of swept source optical coherence tomography imaging system for root canal endoscopy and application in diagnosis of root fractures / 北京大学学报(医学版)
Journal of Peking University(Health Sciences) ; (6): 753-757, 2019.
Article in Chinese | WPRIM | ID: wpr-941883
ABSTRACT
OBJECTIVE@#To construct swept source optical coherence tomography (SS-OCT) imaging system for root canal endoscopy, and to evaluate the accuracy of diagnosing artificial root fractures.@*METHODS@#An ultra-high-speed (40 kHz) swept laser source was developed based on the piezoelectric tuning filter and the Fourier domain mode locking (FDML) swept laser technology (patent number 200620135940.2). Ultra-miniature gradient index lens technology (patent number 201320241218.7) was used to create a thin endoscopic probe with a diameter of 0.86 mm for real-time image transmission. The SS-OCT light source had a wavelength of 1 310 nm and a bandwidth of 100 nm. The axial and transverse image resolutions were 15 μm and 25 μm, respectively. Artificial fractures were created on human mandibular premolars with single root and the premolar roots were prepared to 41 horizontal sections (1 mm thick). 27 root sections with fractures (width 52-284 μm) and 14 the sections without fractures were observed under an optical stereomicroscope with a cold light source as the gold standard. The horizontal root sections were scanned by self-developed SS-OCT imaging system for root canal endoscopy with a central wavelength of 1 310 nm and bandwidth of 100 nm. The data were reconstructed with 30 μm thick slices at an interval of 30 μm. Two observers, a radiologist and an endodontist, were trained and independently evaluated all the reconstructed images blindly. The diagnostic performance of SS-OCT imaging system was calculated, and statistical analysis was performed.@*RESULTS@#SS-OCT root canal endoscopic imaging system composed of high-speed swept laser source, fiber coupler, endoscopic probe, reference arm and differential detector. Root sections could be scanned by SS-OCT and imaged in realtime at a depth of 1 to 2 mm. The kappa value for interobserver agreement was 0.792, and the intraobserver agreement was 1.000 and 0.709 for two observers respectively. All of 27 fractured root sections and 12 of 14 root sections without fractures were accurately diagnosed while 2 unfractured root sections were misdiagnosed. The sensitivity was 1.000 and the specificity was 0.857 for diagnosis of artificial root fractures by SS-OCT. The positive predictive value (PPV), negative predictive value (NPV) and the overall accuracy rate were 0.931, 1.000 and 0.951 respectively.@*CONCLUSION@#The swept source optical coherence tomography imaging system for root canal endoscopy is a promising imaging method for observing root fractures..
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Root Canal Therapy / Tooth Root / Dental Pulp Cavity / Tomography, Optical Coherence / Endoscopy Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Peking University(Health Sciences) Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Root Canal Therapy / Tooth Root / Dental Pulp Cavity / Tomography, Optical Coherence / Endoscopy Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Peking University(Health Sciences) Year: 2019 Type: Article