Your browser doesn't support javascript.
loading
Radiography study on osteotome sinus floor elevation with placed implant simultaneously with no graft augmentation / 北京大学学报(医学版)
Journal of Peking University(Health Sciences) ; (6): 95-101, 2020.
Article in Chinese | WPRIM | ID: wpr-942147
ABSTRACT
OBJECTIVE@#To investigate the change of endo-sinus bone height and bone volume in osteotome sinus floor elevation (OSFE) without bone graft but placing implants simultaneously by using cone beam computed tomography (CBCT) and three dimensional analysis, and to find the impacting factors on endo-sinus bone augmentation.@*METHODS@#OSFE was performed in 38 edentulous patients with missing teeth at posterior maxillary region, and 44 implants were placed and referred for OSFE using no graft materials. CBCT was performed pre-surgery and 9-68 months post-surgery when the patients encountered another implant surgery. The gained bone height at mesial, distal, buccal and palatal sites around the implant in sinus were measured, volumetric measurements of the endo-sinus gained bone volume (ESGBV) in the elevated region were calculated by Mimics software. Univariate analysis and multiple linear regression were performed to investigate the impacting factors on the gained bone height and ESGBV. Marginal bone loss was recorded according to the periapical radiography after implant restoration.@*RESULTS@#The mean residual bone height (RBH) pre-surgery was (3.41±1.23) mm, the mean protruded length (PL) into sinus of implant post-surgery was (3.41±1.28) mm, the mean endo-sinus gained bone height was (2.44±1.23) mm at distal sites, (2.88±1.20) mm at mesial sites, (2.83±1.22) mm at buccal sites and (2.96±1.16) mm at palatal sites, the mean endo-sinus gained bone height at distal sites was significantly lower than the other three sites (P < 0.05). The average endo-sinus gained bone height was (2.78±1.13) mm. The mean ESGBV was (122.15± 73.27) mm3. Univariate analysis showed the more RBH, the less bone height gained in sinus, which existed at buccal, lingual, mesial and distal sites (P < 0.001), and the more RBH, the smaller ESGBV gained (P=0.012). The ESGBV was significantly higher in the subjects whose bone generation period was more than 24 months than those whose bone generation period less than 24 months (P=0.034). The more PL, the more bone height and ESGBV gained (P=0.008). Multivariate analysis showed after adjusting factors of gender, age, smoking, width of sinus floor, thickness of sinus membrane pre-surgery, diameter and length of the implant, PL and bone generation period was positively correlated with mean endo-sinus gained bone height and ESGBV, while RBH negatively correlated with mean endo-sinus gained bone height. During the follow-up, the mean marginal bone loss was 0 (0-1.41) mm and all the implants loaded successfully.@*CONCLUSION@#OSFE without bone graft but with placed implant simultaneously can increase endo-sinus gained bone height and ESGBV. RBH, PL and bone generation period are the significant factors impacting endo-sinus bone augmentation.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteotomy / Radiography / Dental Implants / Bone Transplantation / Treatment Outcome / Dental Implantation, Endosseous / Sinus Floor Augmentation / Maxilla Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Peking University(Health Sciences) Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteotomy / Radiography / Dental Implants / Bone Transplantation / Treatment Outcome / Dental Implantation, Endosseous / Sinus Floor Augmentation / Maxilla Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Peking University(Health Sciences) Year: 2020 Type: Article