Your browser doesn't support javascript.
loading
Effect of malleostapedotomy procedure on 17 cases of congenital middle ear malformation / 中华耳鼻咽喉头颈外科杂志
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 806-811, 2021.
Article in Chinese | WPRIM | ID: wpr-942527
ABSTRACT

Objective:

To conclude the clinical features and the postoperative efficacy of congenital middle ear malformation treated with Malleostapedotomy (MS), and to explore the security and effectiveness of MS surgery.

Methods:

The clinical data of 17 patients (18 ears) with congenital middle ear malformation undergoing MS procedure were analyzed. There were 10 males (11 ears) and 7 females (7 ears), aged from 7 to 48 years. The imaging examination, pure-tone audiometry, intraoperative findings and postoperative hearing improvement of these patients were analyzed and summarized, and software SPSS23.0 was used for statistical analysis. Rusults All the 17 patients (18 ears) presented with hearing loss since childhood on the affected sides. Preoperative high resolution CT (HRCT) of the temporal bone revealed definite malformations in 9 ears (6 ears with incus long process dysplasia and 3 ears with anterior and posterior crus dysplasia). Before surgery, the mean bone conductive hearing threshold at 500, 1 000, 2 000 and 4 000 Hz was (15.6±10.2) dB HL, the mean air conductive hearing threshold was (60.6±9.7) dB HL, and the mean air-bone gap was (45.0±8.9) dB. During the surgery, all 18 ears were found to be accompanied by absence or hypoplasia of incus long process. 12 ears had stapes fixation, 6 ears had oval window atresia. All patients were treated with MS procedure by using Piston. The patients were followed up for 3 months to 1 year. The mean bone conductive hearing threshold was (14.7±8.8) dB HL. The mean air conductive hearing threshold was (37.7±11.6) dB HL, and the mean air-bone gap was (23.0±8.0) dB. There were statistically significant differences in the mean air conductive hearing threshold and mean air-bone gap before and after surgery (P<0.05). While there were no statistically significant differences in the mean bone conductive hearing threshold before and after surgery (P=0.550).

Conclusions:

MS procedure is safe and reliable in patients with congenital middle ear malformation of incus long process dysplasia, stapes fixation or oval window atresia. HRCT is useful in evaluating the major deformity of ossicular chain and facial nerve deformity. However, it is not enough to evaluate the joint of incus-stapes and oval window atresia. MS surgery in middle ear malformation requires advanced surgical experience and skills. The hearing improvement can be significant, even though some air-bone gap after surgery exist.
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Stapes / Retrospective Studies / Treatment Outcome / Ear, Middle / Ear Ossicles / Hearing Loss, Conductive Type of study: Observational study Limits: Child / Female / Humans / Male Language: Chinese Journal: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Stapes / Retrospective Studies / Treatment Outcome / Ear, Middle / Ear Ossicles / Hearing Loss, Conductive Type of study: Observational study Limits: Child / Female / Humans / Male Language: Chinese Journal: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Year: 2021 Type: Article