Your browser doesn't support javascript.
loading
Design and application of arterial blood gas analysis assisted by electronic computation: analysis of two cases attached / 中国小儿急救医学
Chinese Pediatric Emergency Medicine ; (12): 635-640, 2022.
Article in Chinese | WPRIM | ID: wpr-955109
ABSTRACT

Objective:

To make Excel spreadsheet of arterial blood gas analysis to judge the types of acid-base imbalance quickly and accurately, and guide the clinical treatment of acid-base disorders.

Methods:

According to the Henderson-Hasselbalch equation, the compensation formula of acid-base imbalance prediction, the theory of acid-base balance and the related research progress, the analysis process of acid-base balance disorder was settled, and the IF function in Microsoft Office Excel 2003 was used to edit the formula to make Excel spreadsheet for arterial blood gas analysis.Once the pH value, artery blood carbon dioxide pressure (PaCO 2), actual bicarbonate (HCO 3-), sodiumion (Na + ), chlorineion (Cl -) and compensatory time-limited parameters were input, the types of acid-base imbalance can be shown.Arterial blood gas analysis of 185 cases from intensive care unit at Xuzhou Central Hospital was determined by Excel spreadsheet group and manual group respectively, the results and time of judging the type of acid-base imbalance were compared between two groups for statistical analysis.

Results:

The results of acid-base imbalance between two groups were compared, and 42 cases were normal and simple acid-base and the consistent rate was 100%, double acid-base imbalances of 107 cases with the consistent rate of 97.20%, triple acid-base imbalances of 36 cases with the consistent rate of 91.67%.After Kappa consistency test (Kappa value=0.944) and Pair chi-square Test (McNemar-Bowker Test)( P=0.223), the results of two groups were consistent.It took less time to judge the results of normal or simple acid-base imbalance[(32.32±4.26)s vs.(75.88±19.22)s], double acid-base imbalance[(31.28±5.31)s vs.(137.56±37.64)s] and triple acid-base imbalance[(32.98±4.23)s vs.(315.09±89.37)s] by the Excel spreadsheet group compared with the manual group, and the differences were statistically significant ( P<0.01).

Conclusion:

The automatic judging of Excel spreadsheet for arterial blood gas analysis can quickly and accurately determine the types of acid-base imbalance in arterial blood gas analysis and has more advantages for triple acid and base imbalance especially with simple interface and simple operation.And it can avoid the missing judgment of acid and base imbalance when pH is 7.35 to 7.45.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Pediatric Emergency Medicine Year: 2022 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Pediatric Emergency Medicine Year: 2022 Type: Article