Research progress in screw-rod fixation system in the treatment of unstable sacral fracture / 中华创伤杂志
Chinese Journal of Trauma
;
(12): 938-946, 2022.
Article
in Chinese
| WPRIM
| ID: wpr-956526
ABSTRACT
Unstable sacral fracture is usually caused by high-energy trauma. Unstable sacral fracture often results in damage to the mechano-conductive structures of the spine and pelvis and thereby affects walking dysfunction. Treatment of sacral fracture has been a challenge due to the complex local anatomy, unique biomechanics and poor bone quality of the sacrum. The screw-rod fixation system has always played an important role in the treatment of variant sacral fracture and more severe sacral fracture. With the introduction of new technology, the screw-rod fixation system has evolved into a variety of structural types. According to whether the fixation range extends to the spine, it can be divided into two categories including spine-pelvic stabilization techniques and pelvic stabilization techniques. The authors review the progress of the screw-rod fixation system in the treatment of sacral fracture from aspects of biomechanical properties and clinical efficacy, so as to provide a reference for the selection of clinical internal fixation.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Chinese Journal of Trauma
Year:
2022
Type:
Article
Similar
MEDLINE
...
LILACS
LIS