Normal reference range of ultrasound hemodynamics in adult liver transplantation from big data and the analysis of the influencing factors: a single-center retrospective study / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 865-871, 2022.
Article in Chinese | WPRIM | ID: wpr-956664
ABSTRACT

Objective:

To obtain the normal reference range of ultrasound hemodynamic parameters after liver transplantation through big data query and statistical analysis, and to analyze its influencing factors.

Methods:

The clinical liver transplantation Ultrasound Image Database Software V1.0 developed by Tianjin First Center Hospital was used to query adult patients after liver transplantation from December 2012 to June 2021. The ultrasonic hemodynamic parameters including the diameter of portal vein (PVD), the flow velocity of portal vein (PVV), the peak flow velocity of hepatic artery (S), the end diastolic flow velocity of hepatic artery (D), the S/D of hepatic artery, the resistance index of hepatic artery (RI), the diameter of middle hepatic vein (MHVD), the flow velocity of middle hepatic vein (MHVV), the diameter of right hepatic vein (RHVD), the flow velocity of right hepatic vein (RHVV), in the first day (1D), the seventh day (7D), the first month (1M), the sixth month (6M), the first year (1Y), the fifth year (5Y) and the tenth year (10Y) after operation were analyzed statistically, and the 95% reference value range of each parameter was obtained.

Results:

A total of 1 740 patients with 12 242 monitoring results after adult liver transplantation were included, and the longest follow-up time was 22 years. There was no significant change in PVD. PVV decreased slightly from postoperative 1D to long-term follow-up. The S and D of hepatic artery were the highest in group 7D after liver transplantation, and then decreased gradually with the extension of postoperative time. Hepatic artery S/D was the lowest in group 7D after operation, with the extension of monitoring time after liver transplantation, it showed an upward trend, but fluctuated. Hepatic artery RI was the highest in postoperative 1D group, and fluctuated with the extension of monitoring time after liver transplantation. There was no significant change in MHVD and RHVD.MHVV and RHVV were the highest in group 7D after liver transplantation, with the extension of postoperative monitoring time, they showed a decreasing trend and fluctuated. The normal range of each parameter was estimated according to the range of 95% medical reference value. The influencing factors of blood flow monitoring of transplanted liver were analyzed, including the various factors in perioperative period, the surgery, the primary disease before operation, the source of donor, the postoperative infection, rejection, drug damage, individual differences and so on.

Conclusions:

This study obtains the trend of each parameter with the extension of follow-up time and the reference value range of each parameter after liver transplantation, which is of great clinical significance for early detection and diagnosis of postoperative vascular complications. However, the blood flow after adult liver transplantation is affected by many factors. In clinical monitoring, it is necessary to make judgment combined with the individual state of patients and conduct dynamic follow-up.