Value of pulmonary ventilation/perfusion single-photon emission computed tomography and CT imaging in the diagnosis of pulmonary embolism in elderly patients / 中华老年医学杂志
Chinese Journal of Geriatrics ; (12): 827-833, 2022.
Article in Chinese | WPRIM | ID: wpr-957305
ABSTRACT

Objective:

To study the value of ventilation/perfusion single-photon emission computed tomography(SPECT)in combination with a low-dose CT scan(SPECT/CT)in diagnosing pulmonary embolism(PE)in elderly patients.

Methods:

In this retrospective study, data were collected from 279 patients with suspected PE and undergone SPECT/CT between January 2015 and December 2019 at Beijing Hospital, with 163 aged ≥65(the elderly group)and 116 aged <65(the control group). Based on diagnosis confirmed during follow-up as the final diagnosis, the diagnostic efficacy of ventilation/perfusion SPECT/CT in the two age groups was examined.The diagnostic efficacy of ventilation/perfusion SPECT/CT and age-adjusted D-dimer in the elderly group was also compared.The diagnostic efficacy of ventilation/perfusion SPECT/CT and CT pulmonary angiography(CTPA)was compared in 43 elderly patients who had undergone both ventilation/perfusion SPECT/CT and CTPA.

Results:

The sensitivity, specificity and accuracy of ventilation/perfusion SPECT/CT in the elderly group were 96.10%(74/77), 91.86%(79/86)and 93.87%(153/163)in the elderly group and 96.43%(27/28), 94.31%(83/88)and 94.83%(110/116)in the control group, respectively, with no statistically significant difference between the two groups( χ2=0.000, 0.409, 0.116, P=1.000, 0.522, 0.733). The sensitivity, specificity and accuracy of age-adjusted D-dimer were 84.42%(65/77), 63.95%(55/86)and 73.62%(120/163), and were significantly different from those of ventilation/perfusion SPECT/CT(all P<0.05). Among 43 elderly patients undergone ventilation/perfusion SPECT/CT and CTPA, 1 was excluded because the diagnosis based on CTPA was uncertain.The diagnostic sensitivity, specificity and accuracy of ventilation/perfusion SPECT/CT were 96.55%(28/29), 92.31%(12/13)and 95.24%(40/42)and those of CTPA were 65.52%(19/29), 92.31%(12/13)and 73.81%(31/42). They had the same specificity, but there were significant differences in sensitivity and accuracy( P=0.012, 0.022).

Conclusions:

Ventilation/perfusion SPECT/CT has higher accuracy in the diagnosis of PE in elderly patients, compared with CTPA and age-adjusted D-dimer.