Your browser doesn't support javascript.
loading
Factors influencing difference in location of cricothyroid membrane between surface palpation and ultrasonic biplane / 中华麻醉学杂志
Chinese Journal of Anesthesiology ; (12): 444-446, 2022.
Article in Chinese | WPRIM | ID: wpr-957476
ABSTRACT

Objective:

To analyze the factors influencing the difference in location of cricothyroid membrane between traditional surface palpation and ultrasonic biplane.

Methods:

One hundred and seven subjects of both sexes, aged 18 yr, underwent neck ultrasound examination in our hospital from August 2021 to December 2021, were selected.The structure of cervical airway was observed by ultrasound.The subjects in whom the structure of cricothyroid membrane was clearly shown were selected.The middle point of cricothyroid membrane was located by otorhinolaryngologist using surface palpation method and by ultrasonic doctor using ultrasonic biplane method.The distance between two positioning points was measured by a ruler.The subjects were divided into accurate group (distance between two points≤3 mm) and difference group (distance between two points>3 mm). The distance between cricoid cartilage and thyroid cartilage (spacing of cricoid cartilage and thyroid cartilage) and distance between the midpoint of cricothyroid membrane and skin (spacing of cricothyroid membrane and skin) were measured by ultrasound.The neck length and the maximum submaxillary distance in head up were measured by a ruler.The factors influencing the difference in location between the two methods were analyzed by multivariate logistic regression.

Results:

One hundred and four subjects with clear cricoid cartilage and cricothyroid membrane under ultrasound were selected.There were significant differences in the ratio of gender, body mass index (BMI), cricothyroid membrane-skin distance, neck length, and maximum submandibular distance between the two groups ( P<0.05). Multivariate logistic analysis showed that female ( OR=9.091, P<0.001), BMI ( OR=11.214, P=0.001) and increased cricothyroid membrane-skin distance ( OR=5.649, P=0.015) were the factors influencing the difference in location between the two cricothyroid membrane localization methods.

Conclusions:

Female, obesity (BMI>28.0 kg/m 2) and increased distance between cricothyroid membrane and skin are the factors affecting the difference in location of cricothyroid membrane between ultrasonic biplane method and surface palpation method, and bedside ultrasound is recommended for location in those with the factors mentioned above.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2022 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2022 Type: Article