Your browser doesn't support javascript.
loading
Clinical value of remnant lipoproteins and low density lipoprotein cholesterol particle concentration detected by vertical auto profile on the diagnosis of carotid plaque / 中华检验医学杂志
Chinese Journal of Laboratory Medicine ; (12): 704-710, 2022.
Article in Chinese | WPRIM | ID: wpr-958567
ABSTRACT

Objective:

To explore the clinical value of peripheral remnant lipoproteins (RLP), low density lipoprotein cholesterol particle (LDL-P) and sdLDL particle (sdLDL-P) measurement in the diagnosis of carotid plaque, so as to provide practical basis for the accurate diagnosis of carotid plaque and the control of carotid plaque related cardiovascular and cerebrovascular diseases.

Methods:

People who underwent carotid plaque ultrasound examination in Xingtai Third Hospital , from January 2020 to June 2021 were selected as the research object. According to the ultrasound results, they were divided into carotid plaque group ( n=146) and control group without carotid plaque ( n=149). The fasting RLP, LDL-P and sdLDL-P of the two groups were measured by vertical auto profile (VAP) centrifugal separation phase, and the fasting TG and LDL-C were detected by routine mixed phase method. The indexes were compared between the two groups and the true positive rate, true negative rate, false positive rate and false negative rate of the diagnosis of carotid plaque were analyzed. The receiver operating characteristic curve of each test index was drawn, and AUC was used to evaluate the clinical diagnostic value of each test index for carotid plaque.

Results:

The levels of RLP, LDL-P and sdLDL-P in carotid plaque group were significantly higher than those in non-carotid plaque group ([1.07±0.36] mmol/L vs [0.59±0.17] mmol/L,[1 300±370] nmol/L vs [781±215] nmol/L,[435±139] nmol/L vs [156±59] nmol/L, all P<0.01). The true positive rate (78.08% [114/146],81.51% [119/146]) and true negative rate (84.56% [126/149], 86.58%[129/149]) of serum RLP and LDL-P for the diagnosis of carotid plaque were significantly higher than TG (58.90%[86/146], 43.62%[65/149]) and LDL-C (59.59% [87/146], 46.98% [70/149]), and the false positive rate (15.44% [23/149], 13.42% [20/149]) and false negative rate (21.92% [32/146], 18.49% [27/146]) were significantly lower than TG (56.38% [84/149], 41.10% [60/146]) and LDL-C (53.02% [79/149], 40.41% [59/146], all P<0.01). The AUC of the ROC curve of RLP (0.890), LDL-P (0.902) and sdLDL-P (0.973) for the diagnosis of carotid plaque was higher than TG (0.682) and LDL-C (0.712). The AUC of ROC curve of the RLP combined with sdLDL-P (0.977) for the diagnosis of carotid plaque was higher than the RLP and sdLDL-P (all P<0.01).

Conclusion:

The serum RLP, LDL-P and sdLDL-P can be used as indicators of carotid plaque, and their clinical diagnostic value are superior to TG and LDL-C; the combined diagnostic effect of lipoprotein subclass is better than that of single index alone.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2022 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2022 Type: Article