Your browser doesn't support javascript.
loading
Analysis of setup errors of vacuum pad combined with breast bracket fixation in linear accelerator intensity-modulated radiotherapy for breast cancer / 肿瘤研究与临床
Cancer Research and Clinic ; (6): 848-852, 2022.
Article in Chinese | WPRIM | ID: wpr-958948
ABSTRACT

Objective:

To explore the setup errors of vacuum pad combined with breast bracket in linear accelerator intensity-modulated radiotherapy for breast cancer.

Methods:

The clinical data of 72 patients who received linear accelerator intensity-modulated radiotherapy after breast conserving surgery in Hai'an Hospital of Traditional Chinese Medicine from July 2017 to March 2022 were retrospectively analyzed. According to the radiotherapy fixation schemes, they were divided into vacuum pad group (24 patients), breast bracket group (27 patients) and vacuum pad combined with breast bracket group (21 patients). Cone-beam CT was used to analyze the setup errors of the fixation, and the mean value of the overall errors and the standard deviation of the system errors were calculated. The relative factors affecting the fixed setup errors were analyzed.

Results:

There were statistical differences among vacuum pad group, breast bracket group and vacuum pad combined with breast bracket group in the level of forward and backward (Z) direction translation error (2.11±0.41, 2.67±0.26 and 1.79±0.21) and Z direction rotation error (1.14±0.24, 1.05±0.21 and 0.91±0.22) ( F values were 45.86 and 6.21, both P < 0.05). The level of Z direction translation error in vacuum pad group was higher than that in vacuum pad combined with breast bracket group, and the difference was statistically significant ( t = 12.37, P = 0.001). The level of Z direction rotation error in breast bracket group was higher than that in vacuum pad combined with breast bracket group, and the difference was statistically significant ( t = 3.41, P = 0.001). In the breast bracket group, the planning target volume (PTV) extension boundary values in the left and right (X), up and down (Y), and Z directions were 2.02, 2.09 and 1.97; the PTV release boundary values in X, Y and Z directions of the vacuum pad group were 1.81, 2.07 and 2.25; the external boundary values of PTV in X, Y and Z directions of the vacuum pad combined with breast bracket group were 1.13, 1.51 and 1.49. The result of multifactor analysis showed that body mass index (BMI) ( OR = 4.208, 95% CI 1.438-12.312) and breast volume ( OR = 4.023, 95% CI 1.375-11.769) were the independent influencing factors of fixed setup errors (both P < 0.05).

Conclusions:

The application of vacuum pad combined with breast bracket in the fixed setup of linear accelerator intensity-modulated radiotherapy of breast cancer is helpful to reduce the fixed setup errors, but at the same time, the fixed setup errors is affected by the patient's BMI, breast volume and other factors.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Cancer Research and Clinic Year: 2022 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Cancer Research and Clinic Year: 2022 Type: Article