Your browser doesn't support javascript.
loading
Method validation of calycosin-7-O-β-D-glucoside in “Astragalus mongholicus” injection by High-performance liquid chromatography / Монголын Анагаах Ухаан
Mongolian Medical Sciences ; : 43-50, 2021.
Article in English | WPRIM | ID: wpr-974448
ABSTRACT
Introduction@#Calycosin-7-O-β-D-glucoside is a glycosyloxyisoflavone that is calycosin substituted by a beta-D-glucopyranosyl residue at position at 7 via a glycosidic linkage. calycosin-7-O-β-D-glucoside, a calycosin derivative compound derived from Astragali Radix, has protective effect against ischemia/ reperfusion injury as well as bacterial endotoxin-induced vascular cell injury. A joint research team of the “Tsombo Pharm” Co., LTD and the Drug research Institute is conducting an experiment to produce a solution of “Astragalus mongholicusinjection prepared by Astragalus mongholicus bunge.@*Goal @#The aim of this study was to develop the validation method of Calycosin-7-O-β-D-glucoside in “Astragalus mongholicusinjection. @*Material and Methods@#As a test sample “Astragalus mongholicusinjection was produced by “Tsombo pharma” Co., LTD. The starndard Calycosin-7-O-β-D-glucoside was supplied from Xilong Scientific Co., Ltd. The reagent were high-performance liquid chromatography (HPLC) grade acetonitrile, formic acid, methanol and purified water. Shimadzu HPLC (CMB-20 A, UV detector Shimadzu SPD-20A was used as the analytical instrument and the analysis conditions were as follows Table 1.@*Results@#The calibration curves for Calycosin-7-O-β-D-glucoside were made by plotting the peak area versus the concentration for each analyte using regression analysis. Each calibration curve was obtained using six levels of concentrations in the range 12.5-100µg/ml. The linear correlation coefficient (R2) for all calibration curves was higher than 0.9981 for all analytes. The limit of detection and limit of quantitation for Calycosin-7-O-β-D-glucoside were in 10.37 µg/ml and 31.45 µg/ml. Accuracy and precision were assessed by analyzing five sets of samples, independently prepared at low (50%) middle (100%) and high (150%) concentrations. The RSD values of both repeatability and intermediate precision were below 0.68% and 0.618% the accuracy remaining between 95.55 to 101.71%. The resulting accuracy data were satisfactory for the quantitative analysis of Calycosin-7-O-β-D-glucoside in “Astragalus mongholicusinjection.@*Conclusions@#Finally, this method can be employed conveniently, reliably and successfully for the estimation of Calycosin-7-O-β-D-glucoside for routine quality contral and stability studies in “Astragalus mongholicusinjection.

Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Mongolian Medical Sciences Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Mongolian Medical Sciences Year: 2021 Type: Article