Development and verification of high performance liquid chromatography for determination of residual 4-dimethylaminopyridine content in pneumococcal polysaccharide-protein conjugate vaccine / 中国生物制品学杂志
Chinese Journal of Biologicals ; (12): 211-2023.
Article in Chinese | WPRIM | ID: wpr-974736
ABSTRACT
@#Objective To develop and verify a high performance liquid chromatography(HPLC) for determination of residual 4-dimethylamino-pyridine(DMAP)content in pneumococcal polysaccharide-protein conjugate vaccine.Methods A HPLC method for determination of residual DMAP content in pneumococcal polysaccharide-CRM197 protein conjugate vaccine was developed by optimization of type of chromatographic column and composition of mobile phase,verified for specificity,accuracy,repeatability and reproducibility,and determined for limit of detection(LOD),limit of quantitation(LOQ)and linear range.The residual DMAP contents in pneumococcal polysaccharide-CRM197 protein conjugate vaccine of 13 serotypes and the intermediates of 1-cyano-4-dimethylamino pyridinium tetrafluoroborate(CDAP)-activated pneumococcal polysaccharide were determined by the developed method.Results The condition for HPLC was optimized as followsSepax HP-C18 chromatographic column(5 μm,4.6 mm × 250 mm)was adopted,using the mixture of 5 mmol/L sodium heptanesulfonate containing 20 mmol/L potassium dihydrogen phosphate(the pH value was adjusted to 3.0 with phosphoric acid)and acetonitrile at a ratio of 87∶13(v/v)as mobile phase at a detection wavelength of 280 nm,a flow rate of 1 mL/min,a sample load of 10 μL and a column temperature of 35 ℃.The mechanism of samples and solvent for pre-treatment showed no interference to the determination result,indicating good specificity of the developed method.The LOD and LOQ were 3.6 and 14.4 ng/mL respectively,while the linear range was 0.05 ~ 10 μg/mL with a R2value of0.999 9.The spike recovery rate was 83% ~ 105%,while the RSDs in repeatability and reproducibility tests were 0.28% ~0.72% and 7.38% respectively.The residual DMAP contents in pneumococcal polysaccharide-CRM197 protein conjugate vaccine of 13 serotypes were 0.135 ~ 1.635 μg/mL.DMAP was detected in the first step of activation of pneumococcal polysaccharide with CDAP,while no CDAP was detected.Conclusion The developed HPLC method is simple,specific,accurate,repeatable and reproducible,which is effective for quality control of pneumococcal polysac-charide-protein conjugate vaccine.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Biologicals Year: 2023 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Biologicals Year: 2023 Type: Article