@# ObjectiveTo summarize the technique and preliminary outcome of Neuroform stent combined with Guglielmi detachable coil (GDC) to treat wide-necked intracranial aneurysms. Methods32 cases with aneurysms which underwent 32 endovascular procedures performed by using stent were retrospectively analyzed.The ratio of aneurysm neck/body is 1/2~1/1. Results24 aneurysms were completely occluded and other 8 were incompletely (>95%) occluded. Transient ischemia of cerebral occured in 2 cases. 14 aneurysms were followed up 0.5~1 year after. 2 aneurysms of them appeared neck remnant growth.ConclusionUsing Neuroform stent combined with GDC to treat wide-necked intracranial aneurysm may prevent the herniation of GDC into the artery and increase the outcome of wide-necked intacranial aneurysm.