Your browser doesn't support javascript.
loading
Observational study on improvement of hypotension in hemodialysis with blood volume feedback control system / 中华肾脏病杂志
Chinese Journal of Nephrology ; (12): 595-599, 2023.
Article in Chinese | WPRIM | ID: wpr-995022
ABSTRACT

Objective:

To study the effect of blood volume feedback control system on improving intradialytic-hypotension (IDH) in maintenance hemodialysis (MHD) patients.

Methods:

It was a prospective cohort study. Thirty MHD patients with recurrent IDH in the Dialysis Center of the First Affiliated Hospital of Zhejiang University School of Medicine from March 2021 to March 2022 were selected. A self-control study was conducted in MHD patients. The patients were treated with routine hemodialysis in both baseline phase (A1) and reversal phase (A2), while with hemodialysis under the blood volume feedback control system in intervention phase (B). Each phase lasted for 4 weeks (12 hemodialysis sessions). The average occurrences of IDH and IDH-related adverse events (IDH-RAE, stopping dehydration for more than 10 minutes or getting off the hemodialysis machine 10 minutes earlier due to IDH) of each patient between phase A1, B, and A2 were calculated and compared. In a total of 1 080 dialysis records, a logistic regression analysis model was established with age, sex and intervention as independent variables and with the occurrence of IDH-RAE as the outcome.

Results:

A total of 30 eligible patients were included in the study, including 14 males (46.7%) and 16 females (53.3%), aged 63.0 (56.5, 72.5) years old, with a median dialysis age of 84.0 (37.2, 120.0) months. The average times of IDH in 30 MHD patients decreased from 1.17 (0.83, 1.67) in stage A1 (before intervention) to 0.33 (0.25, 0.58) in stage B (after intervention) ( P<0.05). The frequency of IDH-RAE decreased significantly from 0.29 (0.19, 0.47) in stage A1 to 0.17 (0,0.25) in stage B ( P<0.05). Logistic regression analysis results indicated that the use of blood volume feedback control system reduced the risk of IDH-RAE by 53% ( OR=0.47, 95% CI 0.34-0.64, P<0.001).

Conclusions:

The application of blood volume feedback control system can effectively reduce the occurrences of IDH and the risk of IDH-RAE in MHD patients.