Objective:
To establish a solvent desorption-gas chromatography method for the determination of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air.Methods:
The 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air were collected using activated carbon tubes, desorbed with carbon disulfide, and separated and detected by gas chromatography. The quantifications were based on standard curves.Results:
The linear ranges of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane were 0.98-395.50 and 0.87-395.50 mg/L, respectively, with the correlation coefficient of 0.999 95. The detection limits were 0.29 and 0.26 mg/L, respectively. The average of desorption efficiency was 92.04%-104.67%. The within- and between-run relative standard deviations were 1.42%-2.09% and 1.63%-6.09%, respectively. The sampling efficiency was more than 98.00%. The samples could be stored at room temperature for at least 14 days.Conclusion:
This method can be used in detection of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air.