RESUMEN
Introducción:
Cerca del 25% de eventos isquémicos cerebrales son secundarios a fibrilación auricular (FA) paroxística y los pacientes requieren anticoagulación oral permanente. Es necesario identificarlos para prevenir su aparición. El método de rutina utilizado es el Holter de 24 horas. Materiales yMétodos:
En un período de 21 meses, 100 pacientes con diagnóstico presuntivo de un evento cerebrovascular isquémico agudo (ECV) o ataque isquémico transitorio (AIT), de origen embólico, fueron sometidos a monitoreo Holter de 96 horas, para detectar fibrilación auricular paroxística.Resultados:
En 7% de ellos se encontró alguna forma de esta arritmia, así como en 7,8% de aquellos con diagnóstico de ECV o AIT confirmados y sin evidencia de fuente cardioembólica.Discusión:
Concluimos que el método de Holter de 96 horas es mejor que el rutinario de 24 horas, pero para mejorar su sensibilidad, se requiere seleccionar a los pacientes con mayor probabilidad de presentar la arritmia.ABSTRACT
Introduction:
Close to 25% of cerebrovascular events are related to paroxistic atrial fibrillation (AF), that is why AF patients need to receive permanent oral anticoagulation. We need to identify them to prevent the events. The usual test employed has been the 24 hours Holter.Methods:
In a period of 21.5 months, 100 patients with presumptive diagnosis of acute ischemic cerebrovascular event or transient ischemic attack of embolic origin, underwent 96 hours Holter monitoring to detect paroxysmal atrial fibrillation.Results:
In nearly 7% of these patients this kind of arrhythmia was found, as well as, in 7.8% of those with confirmed stroke without evidence of cardioembolic source.Discusion:
We conclude that the 96 hours Holter is better than the routinary 24-hour Holter, though, in order to incresae the sensitivity of this test, it is worthwhile to choose patientes with higher probability to present this arrhytmia.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Fibrilación Atrial
/
Electrocardiografía Ambulatoria
/
Accidente Cerebrovascular
/
Diagnóstico
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
Límite:
Adult
/
Aged
/
Aged80
/
Humans
Idioma:
Es
Revista:
Cambios rev. méd
Asunto de la revista:
MEDICINA
/
SAUDE PUBLICA
Año:
2016
Tipo del documento:
Article