Anesthetic management for patient with severe cyanosis following bioprosthetic valve stenosis / Manejo anestésico de paciente com cianose grave após estenose de valva bioprotética
Rev. bras. anestesiol
;
69(2): 211-213, Mar.-Apr. 2019. graf
Artículo
en Inglés
| LILACS
| ID: biblio-1003395
ABSTRACT
Abstract We presented a 39-year-old female patient with life-threatening hypoxemia after tricuspid valve replacement because of Ebstein's anomaly. And the severe cyanosis is due to bioprosthetic valve stenosis and atrial septal defect. Anesthetic management of a patient with severe obstructive prosthetic valve dysfunction can be challenging. Similar considerations should be given to patients with Ebstein's anomaly to maintain the pressure equalized between the right and left atrial. Transesophageal echocardiography and cerebral oxygen saturation provided real time information in perioperative care.
RESUMO
Resumo Apresentamos o caso de uma paciente de 39 anos, com hipoxemia em risco de vida após a substituição da valva tricúspide devido à anomalia de Ebstein e cianose grave devido à estenose de valva bioprotética e comunicação interatrial. O manejo anestésico de um paciente com disfunção obstrutiva grave de prótese valvar pode ser um desafio. Os pacientes com anomalia de Ebstein também precisam de atenção especial para manter a pressão equalizada entre o átrio direito e o esquerdo. A ecocardiografia transesofágica e a saturação cerebral de oxigênio forneceram informações em tempo real nos cuidados perioperatórios.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Estenosis de la Válvula Tricúspide
/
Cianosis
/
Anomalía de Ebstein
/
Anestésicos
Tipo de estudio:
Estudio de etiología
Límite:
Adulto
/
Femenino
/
Humanos
Idioma:
Inglés
Revista:
Rev. bras. anestesiol
Asunto de la revista:
Anestesiología
Año:
2019
Tipo del documento:
Artículo
País de afiliación:
China
Institución/País de afiliación:
Sichuan University/CN
Similares
MEDLINE
...
LILACS
LIS