Your browser doesn't support javascript.
loading
Reutilização de perfurocortantes na insulinoterapia e sua associação com infecções estafilocóccicas / Re-use of sharps in insulin therapy and their association with staphylococcus infections / Reutilización de punzocortantes en la insulinoterapia y su asociación con infecciones estafilocócicas
Dunes, Cícero Anthonyelson Teixeira; Sousa, José Kleybson de; Oliveira, Maria Tatiana Alves.
Afiliación
  • Dunes, Cícero Anthonyelson Teixeira; Universidade Federal da Paraíba. João Pessoa. BR
  • Sousa, José Kleybson de; Universidade Federal do Ceará. Fortaleza. BR
  • Oliveira, Maria Tatiana Alves; Universidade Federal do Rio Grande do Norte. Natal. BR
Rev. epidemiol. controle infecç ; 9(1): 15-20, 2019. ilus
Article en Pt | LILACS | ID: biblio-1021089
Biblioteca responsable: BR1314.1
RESUMO
Justificativa e

Objetivos:

A insulinização de múltiplas doses é um dos tratamentos utilizados para diabetes. O manejo de seringas, agulhas e canetas na insulinoterapia têm sido descrito como um fator de risco ao desenvolvimento de processos infecciosos, causando dano a integridade da pele e lesões tissulares, facilitando a penetração de patógenos oportunistas. Diante disso, o objetivo desta pesquisa foi avaliar a prática de reutilização desses dispositivos na insulinoterapia e sua relação com o surgimento de contaminação por Staphylococcus sp. em agulhas e riscos de infecções.

Métodos:

Para a coleta de dados foram realizadas entrevistas semi-estruturadas com os participantes da pesquisa acerca dos aspectos da terapia insulínica. A pesquisa entrevistou 15 diabéticos, dos quais 13 (86,7%) do sexo feminino, sendo coletadas 20 agulhas com posterior envio para análise no laboratório de microbiologia da Faculdade Santa Maria.

Resultados:

Foi constatado que 53,3% dos participantes relataram adotar algum cuidado de hiegiene no local da aplicação, 80% reutilizaram a agulha de um a > 7 dias, variando de dois a > 15 aplicações, e 66,7% sentiram alguma reação no local da aplicação. Um total de nove agulhas reutilizadas mostraram-se contaminadas por Staphylococcus sp. após realização de cultura, coloração de Gram, teste da catalase e coagulase.

Conclusão:

Diante dos resultados, pode-se constatar que existe um potencial risco de infecção por Staphylococcus sp. associado à insulinoterapia.(AU)
ABSTRACT
Background and

Objectives:

Multiple dose insulin is one of the treatments used for diabetes. The management of syringes, needles and pens in insulin therapy has been described as a risk factor for the development of infectious processes, causing damage to skin integrity and tissue injuries, facilitating the penetration of opportunistic pathogens. Therefore, the objective of this research was to evaluate the practice of reuse of these instruments in insulin therapy and their relation with the emergence of Staphylococcus sp. contamination in needles and risks of infections.

Methods:

Semi-structured interviews were carried out with the participants of the study on the aspects of insulin therapy. The research interviewed 15 diabetic individuals, of which 13 (86.7%) were female, and 20 needles were collected and sent to the microbiology laboratory at Faculdade Santa Maria.

Results:

53.3% of the participants reported adopting some hygiene care at the application site, 80% reused the needle from one to > 7 days, ranging from 2 to > 15 applications, and 66.7% felt some reaction at the application site. A total of nine reused needles were contaminated with Staphylococcus sp. after culturing, Gram stain, catalase and coagulase tests.

Conclusion:

According to the results, it can be verified that there is a potential risk of infection by Staphylococcus sp. associated with insulin therapy.(AU)
RESUMEN
Justificación y

Objetivos:

Se utiliza la insulinización de múltiples dosis como uno de los tratamientos para la diabetes. El manejo de jeringas, agujas y plumas de injección en la insulinoterapia se considera como un factor de riesgo para el desarrollo de procesos infecciosos, siendo la causa de daños a la piel y de lesiones tisulares, lo que facilita la entrada de patógenos oportunistas. Por lo anterior, esta investigación busca evaluar la práctica de reutilización de estos aparatos en la insulinoterapia y su relación con el surgimiento de contaminación por Staphylococcus sp. en agujas y de riesgos de infecciones.

Métodos:

Para la recopilación de datos, se realizaron entrevistas semiestructuradas con los participantes de la investigación acerca de los aspectos de la terapia con insulina. En el estudio se entrevistó 15 diabéticos, de los cuales 13 (un 86,7%) son del sexo femenino, y se recolectó 20 agujas para enviarlas a análisis en el Laboratorio de Microbiología de la Facultad Santa Maria.

Resultados:

Se constató que el 53,3% de los participantes relataron adoptar algún cuidado de higiene en el lugar de aplicación; el 80% reutilizó la aguja de 1 a > 7 días, oscilando de 2 a > 15 aplicaciones, y el 66,7% tuvo alguna reacción en el lugar de aplicación. El total de nueve agujas reutilizadas estaban contaminadas con Staphylococcus sp. después de la realización de cultivo, tinción de Gram, prueba de la catalasa y coagulasa.

Conclusión:

A partir de los resultados, se comprobó que existe un potencial riesgo de infección por Staphylococcus sp. asociado a la terapia con insulina.(AU)
Asunto(s)
Palabras clave

Texto completo: 1 Índice: LILACS Asunto principal: Autocuidado / Infecciones Estafilocócicas / Insulina Tipo de estudio: Qualitative_research / Risk_factors_studies Límite: Humans Idioma: Pt Revista: Rev. epidemiol. controle infecç Asunto de la revista: SAUDE PUBLICA Año: 2019 Tipo del documento: Article

Texto completo: 1 Índice: LILACS Asunto principal: Autocuidado / Infecciones Estafilocócicas / Insulina Tipo de estudio: Qualitative_research / Risk_factors_studies Límite: Humans Idioma: Pt Revista: Rev. epidemiol. controle infecç Asunto de la revista: SAUDE PUBLICA Año: 2019 Tipo del documento: Article