Evaluation of Tensile Bond Strength of Metallic Prefabricated Posts Cemented with Different Luting Agents
Pesqui. bras. odontopediatria clín. integr
; 20: e4009, 2020. tab, graf
Article
en En
| LILACS, BBO
| ID: biblio-1135547
Biblioteca responsable:
BR1264.1
ABSTRACT
Abstract Objective:
To assess the tensile bond strength of prefabricated metal posts cemented with different luting agents. Material andMethods:
Fifty single-rooted endodontically treated human teeth had their crowns cut, mounted into acrylic-resin blocks and then an 8mm depth post space were prepared. Prefabricated cylindrical metal posts were cemented using different luting agents a zinc phosphate cement (SS White), a conventional glass ionomer cement (Vidrion C), two resin-modified glass ionomer cements (Vitremer and RelyX Luting 2) and a resin cement (RelyX ARC). Samples were stored in distilled water for seven days and then submitted to a tensile bond strength test until complete dislocation of the post. One-way analysis of variance and Tukey test for pairwise multiple comparisons were used to evaluate differences between luting agents.Results:
Tensile bond strength was 563.88±203.41 N for zinc phosphate cement, 336.86 ± 137.64 N for Vidrion C, 515.24 ± 239.48 N for Vitremer, 828.47±433.99 N for RelyX Luting 2 and 1262.51 ± 356.29 for RelyX ARC. The Relyx ARC presented the highest tensile bond strength regard the luting agent tested (p< 0.05).Conclusion:
RelyX ARC presented the higher tensile bond strength compared to the other luting agents evaluated.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Resistencia a la Tracción
/
Cementos de Resina
/
Cementos Dentales
/
Cementos de Ionómero Vítreo
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
País/Región como asunto:
America do sul
/
Brasil
Idioma:
En
Revista:
Pesqui. bras. odontopediatria clín. integr
Asunto de la revista:
ODONTOLOGIA
Año:
2020
Tipo del documento:
Article