Your browser doesn't support javascript.
loading
Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
Ribeiro, Caroline Santos; Perez, Mayra Manoella; Department of Restorative DentistryBenitez-Sellan, Pablo Lenin; Guaré, Renata de Oliveira; Department of Restorative DentistryBresciani, Eduardo; Diniz, Michele Baffi.
  • Ribeiro, Caroline Santos; Cruzeiro do Sul University. Postgraduate Program in Dentistry. São Paulo. BR
  • Perez, Mayra Manoella; Cruzeiro do Sul University. Postgraduate Program in Dentistry. São Paulo. BR
  • Department of Restorative DentistryBenitez-Sellan, Pablo Lenin; São Paulo State University. Institute of Science and Technology. Department of Restorative DentistryBenitez-Sellan, Pablo Lenin. São José dos Campos. BR
  • Guaré, Renata de Oliveira; Cruzeiro do Sul University. Postgraduate Program in Dentistry. São Paulo. BR
  • Department of Restorative DentistryBresciani, Eduardo; São Paulo State University. Institute of Science and Technology. Department of Restorative DentistryBresciani, Eduardo. São José dos Campos. BR
  • Diniz, Michele Baffi; Cruzeiro do Sul University. Postgraduate Program in Dentistry. São Paulo. BR
Artículo en Inglés | LILACS, BBO | ID: biblio-1180857
ABSTRACT
ABSTRACT Objective: To determine the initial mechanical stabilization of conventional glass ionomer cements (GICs) indicated for the atraumatic restorative treatment (ART) in different storage periods. Material and Methods: Specimens were divided according to the GIC (n=12): IZ - Ion-Z, KM - Ketac Molar Easymix, RS - Riva Self Cure, and GL - Gold Label 9. They were prepared and stored in distilled water. Superficial microhardness (SMH) was evaluated (KHN) in three phases: (A) after 1, (B) 3, and (C) 7 days of storage. Data were submitted to 2-way ANOVA and Tukey tests (α = 5%). Results: The average KHN values for phases A, B, and C were, respectively, 33.05 ± 9.74; 33.21 ± 10.31 and 52.07 ± 11.75 (IZ); 50.35 ± 11.39; 66.05 ± 10.48 and 67.77 ± 13.80 (KM); 89.63 ± 15.59; 71.31 ± 23.86 and 57.70 ± 16.89 (RS); 42.18 ± 9.03; 68.54 ± 6.83 and 57.95 ± 8.24 (GL). Significant differences were observed: GIC, time, and interaction of both (p<0.05). KHN values differed between the groups, except in the GIC parameter for KM and GL. The time parameter values of phase A were lower than those of B and C, except for IZ and RS. Conclusion: The initial mechanical stabilization differed between the types of GIC tested and the storage time, and after the final period, all had similar SMH.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Tratamiento Restaurativo Atraumático Dental / Cementos de Ionómero Vítreo / Pruebas de Dureza / Diente Molar País/Región como asunto: America del Sur / Brasil Idioma: Inglés Revista: Pesqui. bras. odontopediatria clín. integr Asunto de la revista: Odontología Año: 2021 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Cruzeiro do Sul University/BR / São Paulo State University/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Tratamiento Restaurativo Atraumático Dental / Cementos de Ionómero Vítreo / Pruebas de Dureza / Diente Molar País/Región como asunto: America del Sur / Brasil Idioma: Inglés Revista: Pesqui. bras. odontopediatria clín. integr Asunto de la revista: Odontología Año: 2021 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Cruzeiro do Sul University/BR / São Paulo State University/BR