Your browser doesn't support javascript.
loading
Correlação entre os métodos sorológico e molecular para detecção do HIV na triagem de doadores de sangue na Fundação HEMOPA / Correlation between sorological and molecular methods for HIV detection in blood donor screening in HEMOPA Foundation
Amaral, Carlos Eduardo de Melo; Cunha, Luanne Rafaela Magalhães; Macedo, Valéria Lobato.
  • Amaral, Carlos Eduardo de Melo; Universidade Federal do Pará - UFPA. Pará. BR
  • Cunha, Luanne Rafaela Magalhães; Centro Universitário Metropolitano da Amazônia. Belém. BR
  • Macedo, Valéria Lobato; Centro Universitário Metropolitano da Amazônia. Belém. BR
Rev. bras. anal. clin ; 53(3): 258-263, 20210930. tab, graf
Artículo en Portugués | LILACS | ID: biblio-1368622
RESUMO

Objetivo:

Buscar a correlação entre os métodos sorológico e molecular para detecção do HIV na triagem de doadores de sangue na Fundação HEMOPA.

Métodos:

Realizou-se a busca das amostras reagentes para HIV, referente aos anos de 2015 a 2019 no Sistema de Banco de Sangue da Fundação HEMOPA. Para análise estatística, utilizou-se o programa SPSS para a comparação das medianas dos valores de S/CO com NAT detectável e indetectável. O teste de X² foi utilizado para apontar a correlação dos valores de S/CO com a presença do RNA viral.

Resultados:

Obtiveram-se para o estudo 910 amostras reagentes, na qual 75,60% (688/910) positivas (S/CO >1,2) e 24,40% (222/910) inconclusivas (S/CO 0,8-1,2). A mediana de S/CO das amostras detectáveis foi de 503,93 e das indetectáveis foi de 1,22 no NAT.

Conclusão:

Estabelecemos que na triagem sorológica-molecular há uma correlação estatisticamente significante, na qual a presença de anticorpos e/ou antígenos no teste ARCHITECH HIV Ag/Ab Combo orienta a predição de viremia no NAT.
ABSTRACT

Objective:

Search for the correlation between serological and molecular methods of HIV detection in screening blood donors at the HEMOPA Foundation.

Methods:

The HIV reagent samples were searched for the years 2015 to 2019 in the Blood Bank System of the HEMOPA Foundation. For statistical analysis, the SPSS program was used to compare the medians of the S / CO values with detectable and undetectable NAT. The X² test was used to point out the correlation between S / CO values and the presence of viral RNA.

Results:

910 reagent samples were obtained for the study, in which 75.60% (688/910) positive (S / CO> 1.2) and 24.40% (222/910) inconclusive (S / CO 0.8) -1.2). The median S / CO of the detectable samples was 503.93 and the undetectable was 1.22 in NAT.

Conclusion:

We established that in serological-molecular screening there is a statistically significant correlation, in which the presence of antibodies and / or antigens in the ARCHITECH HIV Ag / Ab Combo test guides the prediction of viremia in NAT.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Donantes de Sangre / Serodiagnóstico del SIDA Tipo de estudio: Estudio diagnóstico / Estudio de tamizaje Idioma: Portugués Revista: Rev. bras. anal. clin Asunto de la revista: Patología Año: 2021 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Metropolitano da Amazônia/BR / Universidade Federal do Pará - UFPA/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Donantes de Sangre / Serodiagnóstico del SIDA Tipo de estudio: Estudio diagnóstico / Estudio de tamizaje Idioma: Portugués Revista: Rev. bras. anal. clin Asunto de la revista: Patología Año: 2021 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Metropolitano da Amazônia/BR / Universidade Federal do Pará - UFPA/BR