Comparação entre acelerometria e ipaq-versão curta para medir atividade física em estudos populacionais / Comparison of accelerometer and ipaq-sf derived physical activity in population-based study
Rev. bras. ciênc. mov
; 29(4): [1-16], out.-dez. 2021. tab, ilus
Article
en Pt
| LILACS
| ID: biblio-1372101
Biblioteca responsable:
BR1552.1
Ubicación: BR 1552.1
RESUMO
Medidas autorreportadas de atividade física (AF) são comumente usadas em pesquisas populacionais, contudo ainda é incerto o viés destas quando comparadas com acelerometria. Assim, o objetivo deste estudo foi comparar medidas de AF obtidas por questionário e acelerometria em adultos e idosos. Realizouse uma análise transversal do estudo de base populacional denominado Study of Health in Pomerode - SHIP-Brazil, com 2488 participantes entre 20 e 79 anos, conduzido nos anos de 2014/18. Uma subamostra de indivíduos que teve medidas válidas de uso do acelerômetro (ActiGraph GT3X+) e dados do questionário (International Physical Activity Questionnaire-Short Form - IPAQ-SF) foi incluída na análise. As medidas autorreportadas de caminhada e AF de intensidades moderada e vigorosa (AFMV) foram obtidas pelo IPAQ-SF e as medidas mensuradas pelo acelerômetro. Para comparação utilizou-se o teste de Wilcoxon e análise de dispersão de Bland-Altman, com nível de significância p < 0,05. A amostra final foi de 451 pessoas (312 adultos e 103 idosos; 55,2% mulheres; idade média = 49,4 anos ± 13,83). Entre homens adultos houve diferença estatística nas medidas de AFMV entre acelerômetro e IPAQ-SF (p < 0,05). Para os idosos e entre as mulheres adultas e idosas não foi observada diferença estatística na medida de AFMV autorreportada (IPAQ-SF) e acelerômetro (p > 0,05). Em todos os grupos houve maior concordância até valores de 300 minutos/semana de AFMV. Por fim, pode-se concluir que as medidas de AFMV oriundas do IPAQ-SF podem ser utilizadas em estudos populacionais com mulheres e com idosos. Sugere-se cautela na utilização entre homens que tendem a subestimar a AFMV em relação a medida de acelerometria. (AU)
ABSTRACT
Self-reported measures of physical activity (PA) are commonly used in population surveys, however their bias is still uncertain when compared with accelerometry. The goal is to compare PA measurements obtained by questionnaire and accelerometry in adults and the elderly. The Study of Health in Pomerode - SHIP-Brazil database was used, with 2488 participants between 20 and 79 years old, conducted in 2014/18. A subsample of individuals who had valid accelerometer measurements (ActiGraph GT3X+) and questionnaire data (International Physical Activity Questionnaire-Short Form - IPAQ-SF) was included in the analysis. The self-reported measures of walking and moderate and vigorous PA (MVPA) were obtained by the IPAQ-SF and the measured by the accelerometer. For comparison, the Wilcoxon test and Bland-Altman dispersion analysis were used, with significance level p < 0.05. The final sample was 451 people (312 adults and 103 elderly; 55.2% women; mean age = 49.4 years ± 13.83). Among adult men, there was a statistical difference in MVPA measurements between accelerometer and IPAQ-SF (p < 0.05). For the elderly and between adult and elderly women, no statistical difference was observed in the measure of self-reported MVPA (IPAQ-SF) and accelerometer (p > 0.05). In all groups there was greater agreement up to values of 300 minutes / week for MVPA. Finally, it can be concluded that MVPA measures from the IPAQ-SF can be used in population studies with women and the elderly. Caution is suggested in the use among men who tend to underestimate MVPA in relation to the accelerometer measurement. (AU)
Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Epidemiología
/
Encuestas y Cuestionarios
/
Estudio de Validación
/
Acelerometría
/
Actividad Motora
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. ciênc. mov
Asunto de la revista:
MEDICINA ESPORTIVA
Año:
2021
Tipo del documento:
Article