Your browser doesn't support javascript.
loading
Utilidad del dispositivo de potenciación del esfínter esofágico distal (LINX®) para pacientes con reflujo gastroesofágico / Usefulness of the distal esophageal sphincter enhancement device (LINX®) for patients with gastroesophageal reflux
Gaete L, Deycies; Carreño M, Bárbara; Csendes J, Attila; Lanzarini S, Enrique.
  • Gaete L, Deycies; Hospital Clínico Universidad de Chile. Departamento de Cirugía. Santiago. CL
  • Carreño M, Bárbara; Hospital Clínico Universidad de Chile. Departamento de Cirugía. Santiago. CL
  • Csendes J, Attila; Hospital Clínico Universidad de Chile. Departamento de Cirugía. Santiago. CL
  • Lanzarini S, Enrique; Hospital Clínico Universidad de Chile. Departamento de Cirugía. Santiago. CL
Rev. cir. (Impr.) ; 73(5): 602-609, oct. 2021. ilus, tab
Artículo en Español | LILACS | ID: biblio-1388866
RESUMEN
Resumen La fundoplicatura de Nissen laparoscópica (FNL) es el gold standard del tratamiento quirúrgico de pacientes con reflujo gastroesofágico patológico (RGE), con perfil de seguridad y resultados a largo plazo satisfactorios en un 80%. En la última década, se ha propuesto el uso de un dispositivo de potenciación del esfínter esofágico inferior (MSA) comercializado como LINX® (de Ethicon, Johnson & Johnson), como alternativa a la cirugía antirreflujo. El dispositivo consiste en una cadena expansible de cuentas de titanio con un núcleo magnético diseñadas para aumentar el tono del esfínter esofágico inferior (EEI) y evitar su relajación inadecuada. Los resultados preliminares han sido alentadores, sin embargo, no está exento de complicaciones. Las indicaciones más aceptadas son: RGE con motilidad esofágica normal y sin esofagitis erosiva, hernia hiatal < 3 cm, IMC <35 kg/m2 y pacientes sin cirugías gastroesofágicas previas. Se instala por vía laparoscópica. Los efectos adversos más importantes son: disfagia con necesidad de dilataciones endoscópicas, y, retiro del dispositivo, entre 1% y 7% a los 2,5 años. La mayoría de los estudios tienen limitaciones metodológicas, conflictos de interés, falta de resultados objetivos y seguimientos a largo plazo, impidiendo llegar a conclusiones extrapolables respecto a la eficacia del MSA.
ABSTRACT
Laparoscopic Nissen Fundoplication (LNF) is the gold standard of surgical treatment for patients with Gastroesophageal Reflux Disease (GER), with safety profile and long term results satisfactory in 80%. In the last decade, the use of a Lower Esophageal Sphincter Enhancement Device (LESD), marketed as LINX® (from Ethicon, Johnson & Johnson), has been proposed as an alternative to Anti-Reflux Surgery. The device consists of an expandable chain of titanium beads with a magnetic core designed to increase the tone of the lower esophageal sphincter (LES) and prevent its improper relaxation. Preliminary results have been encouraging; however, it is not without complications. The most accepted indications are: GER with normal esophageal motility and without erosive esophagitis, hiatal hernia < 3 cm, BMI <35 kg/m2, and patients without previous gastroesophageal surgeries. It is installed by laparoscopy. The most important adverse effects are: dysphagia with the need for endoscopic dilations, and, removal of the device, between 1 and 7% at 2.5 years. Most of the studies have methodological limitations, conflicts of interest, lack of objective results and long-term follow-up, preventing the reaching of extrapolable conclusions regarding the efficacy of MSA.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Fundoplicación / Implantación de Prótesis Límite: Humanos Idioma: Español Revista: Rev. cir. (Impr.) Asunto de la revista: Cirurgia Geral / Oftalmologia / Ortopedia Año: 2021 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Hospital Clínico Universidad de Chile/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Fundoplicación / Implantación de Prótesis Límite: Humanos Idioma: Español Revista: Rev. cir. (Impr.) Asunto de la revista: Cirurgia Geral / Oftalmologia / Ortopedia Año: 2021 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Hospital Clínico Universidad de Chile/CL