Monitoreo ambiental de sistemas de aclimatización en edificios residenciales y su relación en las micosis respiratorias / Environmental monitoring of air conditioning systems in residential buildings and their relationship with respiratory mycoses
Armada Pacheco, José Manuel; Sinche-Crispín, Fernando Viterbo; Matos-Vila, Gilmer Simón; Arias-Valenzuela, Edverd Nilton; Lapa-Zárate, Carlos Luis.
Afiliación
  • Armada Pacheco, José Manuel; Universidad Continental. Huancayo. PE
  • Sinche-Crispín, Fernando Viterbo; Universidad Nacional de Huancavelica. Huancavelica. PE
  • Matos-Vila, Gilmer Simón; Universidad Nacional de Huancavelica. Huancavelica. PE
  • Arias-Valenzuela, Edverd Nilton; Universidad Nacional de Huancavelica. Huancavelica. PE
  • Lapa-Zárate, Carlos Luis; Universidad Nacional Intercultural Fabiola Salazar Leguía de Bagua. Amazonas. PE
Bol. malariol. salud ambient ; 62(5): 960-967, 2022. tab
Article en Es | LILACS, LIVECS | ID: biblio-1426706
Biblioteca responsable: VE1.1
RESUMEN
En todo el mundo, los cambios climáticos y estilo de vida han resultado en un cambio de ambientes de aire libre a ambientes herméticos y energéticamente eficientes en el hogar y en los lugares de trabajo, donde las personas pasan parte sustancial de su tiempo. En esos entornos, el mantenimiento inadecuado de los aparatos de aire acondicionado, el diseño deficiente de edificio o de los hogares, y las actividades de sus ocupantes pueden dar lugar a condiciones de salud precaria, que pueden incluir enfermedades respiratorias. Bajo un estudio descriptivo, de cohorte transversal, se evaluaron 104 residencias familiares tipo apartamento con sistemas de aclimatización tipo Split en las habitaciones de descanso. Se obtuvieron resultados positivos para dermatofitos en 34 de las 104 muestras (33,65%), mientras que los hongos filamentosos y levaduras fueron 27 casos (25,96%). La concentración osciló entre 17 y 227 UFC/m3 y de 9 a 46 UFC/m3 para dermatofitos y para filamentosos y levaduras, respectivamente. Las especies de hongos dermatofitos aislados en el aire fueron Trichophyton rubrum y Trichophyton mentagrophytes, siendo el más frecuente fue el Trichophyton rubrum que apareció en el 73,52% de las muestras positivas, representamdo una frecuencia de ocurrencia de 24,04%; en ninguna de las muestras se observaron colonias mixtas con ambas especies a la vez. En el grupo de los no dermatofitos, el Penicillium spp. se presento en 10,58% de las muestras evaluadas, siendo el hongo mas prevalente de este grupo, con contajes que alcanzaron hasta 46 UFC/m3. Este grupo en los 27 positivos, se evidencio al menos dos especies de hongos y adicionalmente en 14 casos una levadura. Este estudio demostró que el no aplicar las medidas correctivas y sistema de limpieza de los aires acondiconados puede comprometer la salud de sus habitantes, especialmente por problemas respiratorios, por la presencia de hongos(AU)
ABSTRACT
Throughout the world, climate and lifestyle changes have resulted in a shift from outdoor environments to airtight and energy-efficient environments at home and in workplaces, where people spend a substantial part of their time. In these environments, inadequate maintenance of air conditioners, poor building or home design, and the activities of its occupants can lead to poor health conditions, which may include respiratory diseases. Under a descriptive, cross-sectional cohort study, 104 apartment-type family residences with acclimatization systems in Split-type rest rooms were evaluated. Positive results for dermatophytes were obtained in 34 of the 104 samples (33.65%), while filamentous fungi and yeasts were 27 cases (25.96%). The concentration ranged between 17 and 227 CFU/m3 and from 9 to 46 CFU/m3 for dermatophytes and for filamentous and yeasts, respectively. The species of dermatophyte fungi isolated in the air were Trichophyton rubrum and Trichophyton mentagrophytes, the most frequent being Trichophyton rubrum, which appeared in 73.52% of the positive samples, representing a frequency of occurrence of 24.04%; mixed colonies with both species at the same time were not observed in any of the samples. In the group of non-dermatophytes, Penicillium spp. it was present in 10.58% of the evaluated samples, being the most prevalent fungus of this group, with counts that reached up to 46 CFU/m3. This group in the 27 positives, evidenced at least two species of fungi and additionally in 14 cases a yeast. This study showed that not applying corrective measures and the air conditioning cleaning system can compromise the health of its inhabitants, especially due to respiratory problems, due to the presence of fungi
Asunto(s)
Palabras clave

Texto completo: 1 Índice: LILACS Asunto principal: Monitoreo del Ambiente / Síndrome del Edificio Enfermo / Aire Acondicionado / Estilo de Vida / Enfermedades Pulmonares Fúngicas Tipo de estudio: Evaluation_studies / Observational_studies / Risk_factors_studies Idioma: Es Revista: Bol. malariol. salud ambient Asunto de la revista: CIENCIAS SOCIAIS / MEDICINA TROPICAL Año: 2022 Tipo del documento: Article

Texto completo: 1 Índice: LILACS Asunto principal: Monitoreo del Ambiente / Síndrome del Edificio Enfermo / Aire Acondicionado / Estilo de Vida / Enfermedades Pulmonares Fúngicas Tipo de estudio: Evaluation_studies / Observational_studies / Risk_factors_studies Idioma: Es Revista: Bol. malariol. salud ambient Asunto de la revista: CIENCIAS SOCIAIS / MEDICINA TROPICAL Año: 2022 Tipo del documento: Article