Mayor presión y área de contacto en reparación transósea cruzada de manguito rotador versus reparación simple / Increased pressure and contact area in rotator cuff crossed versus simple transosseous repair
Contreras, Julio José; Liendo, Rodrigo; Soza, Francisco.
  • Contreras, Julio José; Instituto Traumatológico. Santiago. CL
  • Liendo, Rodrigo; Pontificia Universidad Católica de Chile. Santiago. CL
  • Soza, Francisco; Pontificia Universidad Católica de Chile. Santiago. CL
Rev. chil. ortop. traumatol ; 62(3): 159-167, dic. 2021. ilus, tab, graf
Artículo en Español | LILACS | ID: biblio-1427061
RESUMEN

OBJETIVO:

Comparar la presión y el área de contacto en la interfase tendón-huella de una reparación realizada con suturas transóseas simples y cruzadas.

MÉTODOS:

Se utilizaron doce hombros de cordero para simular una rotura de manguito rotador. Se midió el área de contacto en la interfase tendón-huella con láminas sensibles a presión; luego, se midió la presión con un sensor digital. Se registró la presión basal durante la aplicación de carga cíclica y al final de la intervención. Se compararon 2 reparaciones 2 túneles transóseos con nudos simples (TOS; n = 6) y 2 túneles transóseos con nudos cruzados (TOC; n = 6), utilizando FiberWire #2. Se realizaron 1.400 ciclos, con una frecuencia 2,5 Hz y una carga de 5 N. Se utilizó la prueba de Mann-Whitney, y ae consideraron significativos valores de p < 0,05.

RESULTADOS:

La reparación TOS presentó un 50,9 ± 12,7% distribución de presiones en comparación con 72,2 ± 5,3% en la reparación TOC (p < 0,009). La presión promedio en la reparación TOS fue 0,7 ± 0,1 MPa en comparación con 1,1 ± 0,2 MPa en la reparación TOC (p < 0,007). La reparación TOS registró una presión basal de 5,3 ± 5,3 N, presión final de 3,8 ± 4,6 N, y una variación de 51,7 ± 38%. La reparación TOC registró una presión basal de 10,7 ± 1,8 N, presión final de 12,9 ± 8,7 N, y una variación de 114,9 ± 65,9% (p < 0,044; p < 0,022; y p < 0,017, respectivamente).

CONCLUSIÓN:

La reparación TOC presenta mayor presión a nivel de la interfase tendón-hueso, menor pérdida de fuerza de contacto ante cargas cíclicas, y una mejor distribución de fuerza en la huella al comparar con la reparación TOS, lo que se podría traducir en mejor cicatrización tendínea.
ABSTRACT
OBJETIVE To compare the pressure and contact area at the tendon-footprint interface of a repair performed with simple and crossed transosseous sutures.

METHODS:

Twelve lamb shoulders were used to simulate a rotator cuff tear. The contact area at the tendon-footprint interface was measured with pressure-sensitive films; then, the pressure was measured with a digital sensor. The baseline pressure was recorded during the application of a cyclic load and at the end of the intervention. A total of 2 repairs were compared 2 transosseous sutures with single knots (STO; n = 6) and 2 transosseous sutures with crossed knots (TOC; n = 6) using FiberWire #2. In total, 1,400 cycles were performed, with a frequency of 2.5 Hz and a load of 5 N. The Mann-Whitney test was used. Values of p < 0.05 were considered significant.

RESULTS:

The TOS repair presented 50.9 ± 12.7% of pressure distribution compared to 72.2 ± 5.3% in the TOC repair (p < 0.009). The mean pressure in the TOS repair was of 0.7 ± 0.1 MPa compared to 1.1 ± 0.2 MPa in the TOC repair (p < 0.007). The TOS repair registered a basal pressure of 5.3 ± 5.3 N, a final pressure of 3.8 ± 4.6 N, and a variation of 51.7 ± 38%. The TOC repair registered a basal pressure of 10.7 ± 1.8 N, a final pressure of 12.9 ± 8.7 N, and a variation of 114.9 ± 65.9% (p < 0.044; p < 0.022; and p < 0.017 respectively).

CONCLUSION:

The TOC repair presents higher pressure at the tendon-bone interface, less loss of contact force under cyclic loads, and a better distribution of force on the footprint when compared with the TOS repair, which could translate into better tendon healing.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Traumatismos de los Tendones / Manguito de los Rotadores / Procedimientos Ortopédicos Límite: Animales Idioma: Español Revista: Rev. chil. ortop. traumatol Asunto de la revista: Ortopedia / Traumatología Año: 2021 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Instituto Traumatológico/CL / Pontificia Universidad Católica de Chile/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Traumatismos de los Tendones / Manguito de los Rotadores / Procedimientos Ortopédicos Límite: Animales Idioma: Español Revista: Rev. chil. ortop. traumatol Asunto de la revista: Ortopedia / Traumatología Año: 2021 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Instituto Traumatológico/CL / Pontificia Universidad Católica de Chile/CL