Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
Braz. j. oral sci
;
22: e238354, Jan.-Dec. 2023. ilus
Artículo
en Inglés
| LILACS, BBO
| ID: biblio-1442830
ABSTRACT
Aim:
To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implantprosthetic rehabilitation three-dimensionally.Methods:
A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare with other images generated by three laboratory scanners (10 samples per group). Letters identified all the four components A and D angled 45º, and B and C parallel. The BioCAD software exported the images (.STL) to compare and verify deviations of the analogs on the X, Y, and Z axes. The nonparametric Kruskal-Wallis test and the two-way ANOVA on ranks with a post hoc Tukey test analyzed the data with 5% significance.Results:
No statistical differences were observed in the accuracy between the extraoral scanners (p=0.0806). However, when analyzing only the components, component D was more accurate when scanned with Ceramill Map400+ compared with AutoScan DS200+ (p<0.001) and with E2 (p=0.002).Conclusions:
All extraoral systems assessed showed digitalization accuracy but with more deviations in angled implants. The Ceramill Map400+ scanner showed the best results for the digital impression of a complete archAsunto(s)
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Implantes Dentales
/
Técnica de Impresión Dental
/
Prótesis Dental
/
Prótesis Dental de Soporte Implantado
Idioma:
Inglés
Revista:
Braz. j. oral sci
Asunto de la revista:
Odontología
Año:
2023
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
São Paulo State University (UNESP)/BR
/
University Center of Araraquara (UNIARA)/BR