Efetividade da máquina de perfusão hipotérmica versus armazenamento estático para preservação do rim de doador falecido: revisão rápida / Effectiveness of hypothermic machine perfusion versus cold static storage for deceased donor kidney preservation: rapid review
França, Samira Virginia de; Freitas, Luciana da Cunha; Sá, Gleyciane Ferreira Cavalcante; Camargo, Erika Barbosa; Botelho, Raquel Braz Assunção.
  • França, Samira Virginia de; Hospital Universitário de Brasília (HUB-UnB). Brasília. BR
  • Freitas, Luciana da Cunha; Hospital Universitário de Brasília (HUB-UnB). Brasília. BR
  • Sá, Gleyciane Ferreira Cavalcante; Hospital Universitário de Brasília (HUB-UnB). Brasília. BR
  • Camargo, Erika Barbosa; Fundação Oswaldo Cruz. Brasília. BR
  • Botelho, Raquel Braz Assunção; Fundação Oswaldo Cruz (FIOCRUZ). Brasília. BR
Rev. Cient. Esc. Estadual Saúde Pública de Goiás Cândido Santiago ; 9 (Ed. Especial, 1ª Oficina de Elaboração de Pareceres Técnicos Científicos (PTC): 9e9- EE3, 2023. ilus
Artículo en Portugués | LILACS, CONASS, ColecionaSUS, SES-GO | ID: biblio-1524143
RESUMO
Tecnologia máquina de perfusão hipotérmica. Indicação Transplante renal de doador falecido. Pergunta Qual a efetividade da máquina de perfusão hipotérmica (HMP) para a preservação do rim de doador falecido, quando comparada ao armazenamento estático a frio (SCS)? Objetivo. Avaliar a efetividade da máquina de perfusão hipotérmica na preservação do rim de doador falecido, em comparação com o armazenamento estático a frio.

Métodos:

Revisão de revisões sistemáticas (overview) do tipo revisão rápida. Foi realizado um levantamento bibliográfico nas bases de dados PubMed, Embase, BVS, Epistemonikos, Cochrane Library e em bases de registro de protocolos de revisões sistemáticas e ensaios clínicos, utilizando descritores e estratégias de busca predefinidas. A avaliação da qualidade metodológica dos estudos incluídos foi feita através da ferramenta AMSTAR-2 (Assessing the Methodological Quality of Systematic Reviews Version 2).

Resultados:

Duas revisões sistemáticas atenderam aos critérios de elegibilidade e foram incluídas na análise. Uma delas apresentou alto nível de qualidade metodológica.

Conclusão:

O uso da HMP para a preservação de rins de doadores falecidos foi associado a melhores desfechos clínicos relacionados à função retardada e à sobrevida do enxerto e foi considerado custo-efetivo, quando comparado ao SCS. Faz-se necessária a geração de evidências mais robustas acerca dos custos e benefícios do uso desta tecnologia no âmbito do SUS
ABSTRACT
Technology hypothermic machine perfusion. Indication Deceased donor kidney transplantation. Question How effective is hypothermic machine perfusion (HMP) for preserving deceased donor kidneys compared to static cold storage (SCS)?

Objective:

To evaluate the effectiveness of the hypothermic machine perfusion in preserving the deceased donor kidney, compared to static cold storage.

Methods:

Rapid review of systematic reviews (overview). A bibliographic survey was carried out in the databases PubMed, Embase, VHL, Epistemonikos, Cochrane Library and in databases of systematic review protocols and clinical trials, using predefined descriptors and search strategies. The assessment of the methodological quality of the included studies was performed using the AMSTAR-2 tool (Assessing the Methodological Quality of Systematic Reviews Version 2).

Results:

Two systematic reviews met the eligibility criteria and were included in the analysis. One of them performed a high level of methodological quality.

Conclusion:

The use of HMP for the preservation of deceased donor kidneys was associated with better clinical outcomes related to delayed graft function and graft survival and was considered cost-effective. It is necessary to generate more evidence about the costs and benefits of using this technology within the Brazilian Unified System of Healthcare (SUS)
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Preservación de Órganos / Trasplante de Riñón Tipo de estudio: Revisiones Sistemáticas Evaluadas Límite: Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. Cient. Esc. Estadual Saúde Pública de Goiás Cândido Santiago Año: 2023 Tipo del documento: Artículo Institución/País de afiliación: Fundação Oswaldo Cruz (FIOCRUZ)/BR / Fundação Oswaldo Cruz/BR / Hospital Universitário de Brasília (HUB-UnB)/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Preservación de Órganos / Trasplante de Riñón Tipo de estudio: Revisiones Sistemáticas Evaluadas Límite: Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. Cient. Esc. Estadual Saúde Pública de Goiás Cândido Santiago Año: 2023 Tipo del documento: Artículo Institución/País de afiliación: Fundação Oswaldo Cruz (FIOCRUZ)/BR / Fundação Oswaldo Cruz/BR / Hospital Universitário de Brasília (HUB-UnB)/BR