Your browser doesn't support javascript.
loading
Metahemoglobinemia congénita. Reporte de caso / Congenital Methemoglobinemia. A Case Report
Gutiérrez-Riverol, Karla; Lozada Rosete, Karla Guadalupe; Dosta Herrera, Juan José; Cruz Avelar, Agles.
  • Gutiérrez-Riverol, Karla; Hospital de Especialidades Centro Médico Nacional La Raza. Ciudad de México. MX
  • Lozada Rosete, Karla Guadalupe; Hospital de Especialidades Centro Médico Nacional La Raza. Ciudad de México. MX
  • Dosta Herrera, Juan José; Hospital de Especialidades Centro Médico Nacional La Raza. Ciudad de México. MX
  • Cruz Avelar, Agles; Universidad Nacional Autónoma de México. Facultad de Medicina. Ciudad de México. MX
Rev. Fac. Med. UNAM ; 67(1): 17-21, ene.-feb. 2024. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1559096
RESUMEN
Resumen La metahemoglobinemia ocasionalmente causa cianosis, particularmente cuando es congénita. Debido a sus vías enzimáticas deficientes y a la disminución de la capacidad de transporte de oxígeno, para los pacientes con metahemoglobinemia congénita es importante evitar la exposición a agentes oxidantes. A continuación, presentamos un paciente pediátrico con metahemoglobinemia congénita no diagnosticada preoperatoriamente que fue sometido a cateterismo con diagnóstico probable de hipertensión pulmonar bajo anestesia general. El paciente pediátrico era un niño de 10 años que presentaba una lectura de oximetría de pulso (SpO2) 92% antes de la inducción de la anestesia. La metahemoglobinemia se sospechó intraoperatoriamente por primera vez debido a un desajuste de la SpO2 de la oximetría de pulso digital y la SaO2 (saturación arterial de oxígeno), y luego se confirmó mediante múltiples longitudes de onda con la CO-oximetría. Se discuten la fisiopatología, etiología, manifestaciones clínicas, consideraciones anestésicas y opciones de tratamiento de la metahemoglobinemia.
ABSTRACT
Abstract Methemoglobinemia occasionally causes cyanosis particularly in congenital methemoglobinemia. Avoidance of exposure to oxidizing agents is important for patients with congenital methemoglobinemia because of their deficient enzymatic pathways and decreased oxygen-carrying capacity. Here, we present a pediatric patient with preoperatively undiagnosed congenital methemoglobinemia who underwent catheterization with probably diagnosis of pulmonar hypertension under general anesthesia. The pediatric patient was a 10-year-old who displayed a low pulse oximetry reading of 92% prior to induction of anesthesia. Methemoglobinemia was first suspected intraoperatively because of a mismatch of SpO2 of finger pulse oximetry and SaO2 of arterial blood, and was later confirmed by multiplewavelength CO-oximetry. The pathophysiology, etiology, clinical manifestations, anesthetic considerations, and treatment options of methemoglobinemia are discussed.


Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. Fac. Med. UNAM Asunto de la revista: Medicina Año: 2024 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Hospital de Especialidades Centro Médico Nacional La Raza/MX / Universidad Nacional Autónoma de México/MX

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. Fac. Med. UNAM Asunto de la revista: Medicina Año: 2024 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Hospital de Especialidades Centro Médico Nacional La Raza/MX / Universidad Nacional Autónoma de México/MX