RESUMO
INTRODUÇÃO:
A cirurgia plástica da mama, por se tratar de um dos procedimentos mais realizados no nosso meio, traz consigo muitas variações técnicas e de táticas cirúrgicas, que proporcionam ao profissional da área da Cirurgia Plástica várias opções técnicas. O objetivo foi avaliar a técnica do retalho superior delgado nas mamoplastias.MÉTODOS:
Foram selecionadas 30 pacientes, no período de 2 anos, que apresentavam hipertrofia mamária e/ou ptose mamária. Foi realizada uma técnica utilizando a marcação em T invertido e um retalho inferior número IV de Ribeiro. A modificação introduzida foi a confecção do retalho superior delgado com aproximadamente 2 cm de espessura computando 30% do volume mamário, sendo o retalho inferior responsável por 70% do volume.RESULTADOS:
Três colegas especialistas em Cirurgia Plástica por mais de 10 anos avaliaram as pacientes e pudemos observar um resultado no qual 91,5% das pacientes avaliadas se mostraram de ótima qualidade, 6,9% de boa qualidade e apenas 1,6% de resultados regulares, sem resultados ruins. Foram computados 2,6% de complicações, com um caso de infecção, um de assimetria e dois de cicatriz inestética.CONCLUSÃO:
O retalho superior delgado se mostrou muito eficaz nas mamoplastias.ABSTRACT
INTRODUCTION:
For being one of the procedures mostly performed in our environment, breast plastic surgery involves many technical variations and surgical strategies that provide the plastic surgeon with several options. The objective of this study was to evaluate the use of thin superior flap technique in mammoplasties.METHODS:
Over a period of 2 years, we selected 30 patients presenting with mammary hypertrophy and/or breast ptosis. A technique based on the inverted-T marking and Ribeiro's type IV inferiorly based flap was carried out. The intervention involved the production of a thin superior flap with a thickness of approximately 2 cm. This comprised 30% of the breast volume, while the inferior flap was responsible for the remaining 70%.RESULTS:
Three expert plastic surgeons evaluated the patients. The results showed that 91.5% of the women who underwent this procedure presented with excellent quality outcomes, while 6.9% had a good outcome. Further, a fair outcome was observed only in 1.6% of the patients, while poor outcomes were not obtained. The procedure had a complication rate of 2.6%, which included one case of infection, one of asymmetry, and two of unsightly scars.CONCLUSION:
The thin superior flap proved to be very effective in mammoplasties.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Colgajos Quirúrgicos
/
Mama
/
Procedimientos de Cirugía Plástica
/
Estudio de Evaluación
/
Glándulas Mamarias Humanas
/
Hipertrofia
Tipo de estudio:
Evaluation_studies
Límite:
Adult
/
Female
/
Humans
Idioma:
En
/
Pt
Revista:
Rev. bras. cir. plást
Asunto de la revista:
CIRURGIA GERAL
Año:
2016
Tipo del documento:
Article