Evaluación físico matemática de la dinámica cardiaca arrítmica mediante la aplicación de la ley exponencial caótica / Physical mathematical evaluation of the arrhythmic cardiac dynamic by means of the application of the chaotic exponential law / Avaliação físico matemática da dinâmica cardíaca arrítmica mediante a aplicação da lei exponencial caótica
Med. U.P.B
; 33(2): 98-105, jul.-dic. 2014.
Article
en Es
| LILACS, COLNAL
| ID: biblio-836894
Biblioteca responsable:
CO101
Ubicación: CO101
RESUMEN
Objetivo:
confirmar la aplicabilidad clínica de la ley exponencial de ayuda diagnóstica específicamente en arritmias y evaluar la concordancia diagnóstica del mismo con respecto al Gold Estándar, por medio del cálculo de la sensibilidad, especificidad y el coeficiente Kappa.Metodología:
se realizó un estudio de 40 Holter, 10 corresponden a sujetos normales y 30 diagnosticados con diferentes tipos de arritmias. Se realizó una simulación teórica de todas las frecuencias cardiacas de mínimo 21 horas a partir de los valores máximos y mínimos de frecuencias registrados, para construir el atractor de la dinámica cardiaca. Seguidamente se calculó la dimensión fractal del atractor y se cuantificó la ocupación espacial de cada uno ellos en el espacio generalizado de Box-counting. Finalmente, se aplicaron los parámetros matemáticos que diferencian dinámicas cardiacas normales de enfermas y agudas, así como en evolución hacia la enfermedad.Resultados:
los casos con arritmias diagnosticados matemáticamente con dinámica aguda fueron seis, se encontraron 24 casos entre los rangos de 73 y 200 de ocupación de la rejilla Kp, que corresponden a casos de evolución hacia agudización de la dinámica. El diagnóstico físico-matemático, después de ser comparado con el Gold Estándar, presentó una sensibilidad y especificidad del 100% y un coeficiente Kappa de uno.Conclusiones:
la aplicación de esta metodología al estudio de la dinámica cardiaca caótica, evidencia su utilidad como herramienta de ayuda diagnóstica para la predicción y prevención de eventos arrítmicos agudos que pueden implicar situaciones con riesgo vital.ABSTRACT
Objective:
To confirm the clinical applicability of the diagnostic methodology based on the power law of cardiac dynamic systems, specifically for detecting arrhythmias, evaluating its concordance with respect to the Gold Standard, by means of the sensitivity, specificity, and Kappa coefficient.Methods:
Forty Holter were studied, of which 10 corresponded to normal subjects and 30 to patients diagnosed with different types of arrhythmias. A theoretical simulation of all cardiac frequencies (of at least 21 hours) was performed from the maximum and minimum frequency values registered, to build the cardiac dynamics attractor and its fractal dimension was calculated; the spatial occupation of each one of them was quantified in the generalized Box-Counting space. Finally, the mathematical parameters to differentiate normality of acute cardiac disease and of the evolution toward disease were applied.Results:
There were six cases with mathematically-diagnosed acute arrhythmias, 24 cases were between 73 and 200 occupied ranges for the Kp grid that correspond to cases of evolution toward disease. This physical-mathematical diagnosis was compared with the Gold Standard and yielded a sensitivity and specificity of 100% and a Kappa coefficient of 1.Conclusions:
The application of this method to the study of chaotic cardiac dynamics evidences its usefulness as a tool of diagnostic aid for the prediction of acute arrhythmic events which may imply situations of vital risk.RESUMO
Objetivo:
confirmar a aplicabilidade clínica da lei exponencial de ajuda diagnóstica especificamente em arritmias e avaliar a concordância diagnóstica do mesmo com respeito ao Gold Estándar, por meio do cálculo da sensibilidade, especificidade e o coeficiente Kappa.Metodologia:
se realizou um estudo de 40 Holter, 10 correspondem a sujeitos normais e 30 diagnosticados com diferentes tipos de arritmias. Se realizou una simulação teórica de todas as frequências cardíacas de mínimo 21 horas a partir dos valores máximos e mínimos de frequências registrados, para construir o atractor da dinâmica cardíaca. Seguidamente se calculou a dimensão fractal do atractor e se quantificou a ocupação espacial de cada um deles no espaço generalizado de Box-counting. Finalmente, se aplicaram os parâmetros matemáticos que diferenciam dinâmicas cardíacas normais de doentes e agudas, assim como em evolução para a doença.Resultados:
os casos com arritmias diagnosticados matematicamente com dinâmica aguda foram seis, se encontraram 24 casos entre as faixas de 73 e 200 de ocupação da grade Kp, que correspondem a casos de evolução para o agravamento da dinâmica. O diagnóstico físico-matemático, depois de ser comparado com o Gold Estándar, apresentou uma sensibilidade e especificidade de 100% e um coeficiente Kappa de um.Conclusões:
a aplicação desta metodologia ao estudo da dinâmica cardíaca caótica, evidência sua utilidade como ferramenta de ajuda diagnóstica para a predição e prevenção de eventos arrítmicos agudos que possam implicar situações com risco vital.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Enfermedades Cardiovasculares
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Límite:
Adult
/
Aged
/
Aged80
/
Humans
Idioma:
Es
Revista:
Med. U.P.B
Asunto de la revista:
MEDICINA
Año:
2014
Tipo del documento:
Article