Your browser doesn't support javascript.
loading
Artificial urinary sphincter revision for urethral atrophy: comparing single cuff downsizing and tandem cuff placement
Linder, Brian J; Viers, Boyd R; Ziegelmann, Matthew J; Rivera, Marcelino E; Elliott, Daniel S.
  • Linder, Brian J; Mayo Clinic. Department of Urology. Rochester. US
  • Viers, Boyd R; Mayo Clinic. Department of Urology. Rochester. US
  • Ziegelmann, Matthew J; Mayo Clinic. Department of Urology. Rochester. US
  • Rivera, Marcelino E; Mayo Clinic. Department of Urology. Rochester. US
  • Elliott, Daniel S; Mayo Clinic. Department of Urology. Rochester. US
Int. braz. j. urol ; 43(2): 264-270, Mar.-Apr. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-840822
ABSTRACT
ABSTRACT Objective To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. Materials and Methods We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Results Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). Conclusions There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Reoperación / Uretra / Incontinencia Urinaria de Esfuerzo / Esfínter Urinario Artificial / Implantación de Prótesis Tipo de estudio: Estudio de etiología / Estudio observacional / Estudio pronóstico / Factores de riesgo Límite: Anciano / Aged80 / Femenino / Humanos / Masculino Idioma: Inglés Revista: Int. braz. j. urol Asunto de la revista: Urología Año: 2017 Tipo del documento: Artículo País de afiliación: Estados Unidos Institución/País de afiliación: Mayo Clinic/US

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Reoperación / Uretra / Incontinencia Urinaria de Esfuerzo / Esfínter Urinario Artificial / Implantación de Prótesis Tipo de estudio: Estudio de etiología / Estudio observacional / Estudio pronóstico / Factores de riesgo Límite: Anciano / Aged80 / Femenino / Humanos / Masculino Idioma: Inglés Revista: Int. braz. j. urol Asunto de la revista: Urología Año: 2017 Tipo del documento: Artículo País de afiliación: Estados Unidos Institución/País de afiliación: Mayo Clinic/US