Implante percutáneo de válvula aórtica con apoyo de circulación extracorpórea en paciente con insuficiencia aórtica severa / Trans catheter aortic valve implantation with extra corporeal circulation support in a patient with severe aortic insufficiency
Rev. chil. cardiol
; 36(1): 41-45, 2017. ilus
Article
en Es
| LILACS
| ID: biblio-844308
Biblioteca responsable:
CL1.1
ABSTRACT
An 84-year man with prior coronary artery bypass surgery and endovascular repair of an abdominal aortic aneurysm developed congestive heart failu-re. He had calcific aortic valve disease with severe regurgitation. A #29 Edwards-Sapien aortic valve via trans-apical approach was implanted with the patient connected to extra corporeal circulation. The patient recovered successfully and remained in functional class II 8 months after hospital dis-charge.
Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Insuficiencia de la Válvula Aórtica
/
Oxigenación por Membrana Extracorpórea
/
Implantación de Prótesis de Válvulas Cardíacas
Límite:
Aged
/
Aged80
/
Humans
/
Male
Idioma:
Es
Revista:
Rev. chil. cardiol
Asunto de la revista:
CARDIOLOGIA
Año:
2017
Tipo del documento:
Article