Your browser doesn't support javascript.
loading
Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque / Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torque
São Paulo; s.n; 2012. 144 p. ilus, tab, graf. (BR).
Tesis en Portugués | LILACS, BBO | ID: biblio-866267
RESUMO
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da prótese sobre implante. Contudo, ainda é frequente encontrar componentes que falham no desempenho, levando à falência da restauração, especialmente quando esses componentes não são bem ajustados, bem fixados ou, ainda, não possuem, na sua geometria, características suficientes para suportar as forças laterais e oclusais de um ciclo mastigatório. O objetivo deste estudo é avaliar a influência do jateamento com óxido de alumínio sobre a superfície externa dos componentes protéticos, separadamente e em conjunto, com um adesivo industrial, em uma tentativa de aumentar os valores de torque de abertura de componentes apertados em seu torque recomendado, pelo fabricante ou menor. Neste ensaio, foram utilizados 36 implantes da marca Straumann®, de 10mm de comprimento com diâmetro de 4,8 mm, os quais foram divididos em 6 grupos Grupo 1 = controle, torque de 35 N.cm; Grupo 2 = superfície jateada com óxido de alumínio (# 320) e torque de 35 N.cm; Grupo 3 = superfície jateada com óxido de alumínio (# 320) e torque de 25 N.cm; Grupo 4 = superfície jateada com óxido de alumínio (# 100) e torque de 25 N.cm; Grupo 5 = superfície jateada com óxido de alumínio (# 320), aplicação de adesivo e torque de 25 N.cm; Grupo 6 = superfície jateada com óxido de alumínio (# 100), aplicação de adesivo e torque de 25 N.cm, que receberam componentes protéticos sólidos de 5,5 mm de altura, regulares e alterados. As modificações incluídas foram o jateamento com partículas de óxido de alumínio (100 e 320 micra) e o uso de Loctite® 277 como adesivo industrial.
ABSTRACT
Problems with design of prosthetic implant connections, microleakage,! loosening which leads to loss of rehabilitative prosthetic structures are frequent topics of dental study. Morse taper connections, due to its characteristics, decreased the rate of these problems opening a new perspective to the success of the prosthesis supported over implant. However, it is still frequent to find components that fail in performance leading to failure of restoration especially when these components are not well adjusted, tightened or do not have in its geometry enough characteristics to support the occlusal and lateral forces in a masticatory cycle. The aim of this study is to evaluate the influence of blasting with aluminum oxide on the outer surface of the prosthetic components separately and in conjunction with an industrial adhesive in an attempt to increase the opening torque values of components tightened on their recommended torque by the manufacturer or less, therefore allowing the dentist an early intervention in the prosthetic rehabilitation. In this test, 36 Straumann® implants of 10mm high and 4,8mm wide were used. They were divided into six groups Group 1 Solid abutments control group - 35 N.cm tightened; Group 2 - Solid sandblasted abutments, 35 N.cm aluminum oxide 320 microns size particles; Group 3 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles; Group 4 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles; Group 5 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles with glue application; Group 6 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles with glue application, which received 5,5 mm high regular and modified solid abutments.
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Prótesis e Implantes / Implantes Dentales / Recubrimientos Dentinarios Idioma: Portugués Año: 2012 Tipo del documento: Tesis

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Prótesis e Implantes / Implantes Dentales / Recubrimientos Dentinarios Idioma: Portugués Año: 2012 Tipo del documento: Tesis