Your browser doesn't support javascript.
loading
Evaluación de torque de remoción en implantes dentales 3i, B&W y tree-oss. estudio experimentalen conejos / Evaluation of removal torque in 3i, B&W and tree-oss dental implants. an experimental study in rabbits
Bustos Malberti, Sebastián; Correa Patiño, Diego; Crespo, Ignacio; Juaneda, María Agustina; Ibáñez, María Constanza; Ibáñez, Juan Carlos.
  • Bustos Malberti, Sebastián; s.af
  • Correa Patiño, Diego; s.af
  • Crespo, Ignacio; s.af
  • Juaneda, María Agustina; Universidad Católica de Córdoba. Facultad de Medicina. Carrera de Especialización en Implantología Oral. Córdoba. AR
  • Ibáñez, María Constanza; Universidad Católica de Córdoba. Facultad de Medicina. Carrera de Especialización en Implantología Oral. Córdoba. AR
  • Ibáñez, Juan Carlos; Universidad Católica de Córdoba. Facultad de Medicina. Carrera de Especialización en Implantología Oral. Córdoba. AR
Rev. Asoc. Odontol. Argent ; 104(4): 150-159, oct.-dic. 2016. ilus, tab
Artículo en Español | LILACS | ID: biblio-869379
RESUMEN

Objetivo:

evaluar el torque de remoción de tres implantes con superficies diferentes, a los 60 días de inserción. Materiales y

métodos:

se midió la frecuencia de resonancia inicial y final y torque de remoción a los 60 días en 18 implantes Biomet 3i (Palm Beach Gardens, FL, Estados Unidos); n=6; B&W (Buenos Aires, Argentina), n=6; Tree-Oss (Buenos Aires, Argentina), n=6; todos de 8,5 mm de longitud y 4 mm de diámetro. Los datos fueron sometidos al test no paramétrico de Mann-Whitney, al de Kruskal-Wallis y al de Wilcoxon.

Resultados:

la media de torque de remoción fue de 82,58 Ncm para implantes Biomet 3i; de 78,08 Ncm para B6W; y de 69 Ncm para Tree-Oss, sin diferencias estadísticamente significativas (p=0,220). La media de ISQ inicial y final fue de 57, 17 y 70,33 para Biomet 3i; de 56,33 y 62,07 para B6W y de 58,17 y 54,5 para Tree-Oss.

Conclusión:

los tres grupos de implantes presentan valores de torque de remoción similares, sin diferencias estadísticamente significativas pero con diferencias significativas en relación a ISQ final.
ABSTRACT

Aim:

to evaluate the removal torque of three implants with different surfaces placed in rabbit femur, 60 days afterinsertion and to compare the implant stability quotient rightafter insertion and 60 days later.Materials and

methods:

Initial and final resonance frequency analysis and removal torque were measured at day60, in 18 parallel wall implants Biomet 3i (Palm Beach Gardens, FL, USA), n=6; B&W (Buenos Aires, Argentina), n=6; Tree-Oss (Buenos Aires, Argentina), n=6; of 8.5 mm in lengthand 4 mm in diameter, placed in the femur of 6 rabbits. Datacollected were analyzed by nonparametric Mann-Whitney, Kruskal-Wallis and Wilcoxon tests.

Results:

The mean removal torques were 82,58 Ncm forBiomet 3i, 78,08 Ncm for B&W and 69 Ncm for Tree-Oss. Differences were not statistically significant (p=0.220). Inassessing initial and final ISQ, the averages obtained for Biomet3i were 57.17 and 70.33, respectively; for B&W 56.33 and62.67, and 58.17 and 54.5 for Tree-Oss.

Conclusion:

It is concluded that the three groups presented similar removal torque values with no statistically significant differences between them, but there were significant differences in relation to final ISQ.
Asunto(s)

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Propiedades de Superficie / Torque / Remoción de Dispositivos / Implantación Dental Endoósea Límite: Animales Idioma: Español Revista: Rev. Asoc. Odontol. Argent Asunto de la revista: Odontología Año: 2016 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Universidad Católica de Córdoba/AR

Similares

MEDLINE

...
LILACS

LIS

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Propiedades de Superficie / Torque / Remoción de Dispositivos / Implantación Dental Endoósea Límite: Animales Idioma: Español Revista: Rev. Asoc. Odontol. Argent Asunto de la revista: Odontología Año: 2016 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Universidad Católica de Córdoba/AR